Related Experiment Video
Updated: Jul 2, 2026

Reverse Total Shoulder Arthroplasty
Published on: July 5, 2011
Humeral head translation during glenohumeral abduction following computer-assisted shoulder hemiarthroplasty
A E Kedgley1, J A DeLude, D S Drosdowech
1Hand and Upper Limb Centre, St Joseph's Health Care London, 268 Grosvenor Street, London, Ontario, Canada.
Abstract:
This study compared the effect of a computer-assisted and a traditional surgical technique on the kinematics of the glenohumeral joint during passive abduction after hemiarthroplasty of the shoulder for the treatment of fractures. We used seven pairs of fresh-frozen cadaver shoulders to create simulated four-part fractures of the proximal humerus, which were then reconstructed with hemiarthroplasty and reattachment of the tuberosities. The specimens were randomised, so that one from each pair was repaired using the computer-assisted technique, whereas a traditional hemiarthroplasty without navigation was performed in the contralateral shoulder. Kinematic data were obtained using an electromagnetic tracking device. The traditional technique resulted in posterior and inferior translation of the humeral head. No statistical differences were observed before or after computer-assisted surgery. Although it requires further improvement, the computer-assisted approach appears to allow glenohumeral kinematics to more closely replicate those of the native joint, potentially improving the function of the shoulder and extending the longevity of the prosthesis.