Analytical and environmental aspects of the flame retardant tetrabromobisphenol-A and its derivatives

Adrian Covaci1, Stefan Voorspoels, Mohamed Abou-Elwafa Abdallah

  • 1Toxicological Centre, Department of Pharmaceutical Sciences, University of Antwerp, Universiteitsplein 1, B-2610 Wilrijk, Belgium. adrian.covaci@ua.ac.be

Related Concept Videos

Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene01:13

Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene

Bromination and chlorination of aromatic rings by electrophilic aromatic substitution reactions are easily achieved, but fluorination and iodination are difficult to achieve. Fluorine is so reactive that its reaction with benzene is difficult to control, resulting in poor yields of monofluoroaromatic products. To address this, Selectfluor reagent is used as a fluorine source in which a fluorine atom is bonded to a positively charged nitrogen.
Electrophilic Aromatic Substitution: Chlorination and Bromination of Benzene01:15

Electrophilic Aromatic Substitution: Chlorination and Bromination of Benzene

Chlorination and bromination are important classes of electrophilic aromatic substitutions, where benzene reacts with chlorine or bromine in the presence of a Lewis acid catalyst to give halogenated substitution products. A Lewis acid such as aluminium chloride or ferric chloride catalyzes the chlorination, and ferric bromide catalyzes the bromination reactions. During the bromination of alkenes, bromine polarizes and becomes electrophilic. However, in the bromination of benzene, the bromine...
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
Flame Photometry: Overview01:02

Flame Photometry: Overview

Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
Reactions at the Benzylic Position: Halogenation01:11

Reactions at the Benzylic Position: Halogenation

Benzylic halogenation takes place under conditions that favor radical reactions such as heat, light, or a free radical initiator like peroxide.
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...