Spurious hyperkalaemia due to EDTA contamination: common and not always easy to identify
Michael P Cornes1, Clare Ford, Rousseau Gama
1Department of Clinical Chemistry, New Cross Hospital, Wolverhampton, West Midlands WV10 0QP. cornesmp@aol.com
Background:
To study the detection and prevalence of spurious hyperkalaemia due to potassium ethylenediaminetetra-acetic acid (kEDTA) contamination.
Methods:
In a one-month prospective study, serum EDTA, zinc, calcium, magnesium concentrations and alkaline phosphatase activity were measured in samples with serum potassium >or=6.0 mmol/L.
Results:
Twenty-eight out of 117 hyperkalaemic samples were contaminated with EDTA. Only serum zinc values below the reference range had 100% sensitivity for indicating EDTA contamination, but even at an optimal specificity of 89% at least 12 potentially genuine hyperkalaemic samples would be rejected.
Conclusion:
Spurious hyperkalaemia due to kEDTA contamination is common. Gross kEDTA contamination is obvious by marked unexpected hyperkalaemia, hypocalcaemia, hypomagnesaemia and hypozincaemia. Spurious hyperkalaemia due to low concentrations of kEDTA contamination can only be confidently detected by measurement of serum EDTA.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
12:11ELIME (Enzyme Linked Immuno Magnetic Electrochemical) Method for Mycotoxin Detection
Published on: October 23, 2009
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
EDTA: Indirect and Alkalimetric Titration
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
EDTA: Auxiliary Complexing Reagents
Complexometric EDTA Titration Curves
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...
