Related Experiment Video
Updated: Jul 2, 2026

Classical Short-Delay Eyeblink Conditioning in One-Year-Old Children
Published on: September 1, 2018
Eyeblink frequency and type in relation to 3- and 9-o'clock staining and gas permeable contact lens variables
Eef Van Der Worp1, John De Brabander, Helen Swarbrick
1Eye Research Institute Maastricht, Department of Ophthalmology, Academic Hospital, Maastricht University, The Netherlands. e.v.d.worp@tip.nl
Purpose:
The primary goal of this study was to evaluate if there is a difference in frequency and in completeness of eyeblinks (type of eyeblink) in rigid gas permeable (GP) lens wearers experiencing 3- and 9-o'clock staining compared with GP lens wearers without substantial staining and nonlens wearers.
Methods:
The study involved 26 nonlens wearers and 55 GP contact lens wearers, with and without 3- and 9-o'clock staining. Every eyeblink over a 5-min period was categorized as a complete eyeblink, incomplete eyeblink, or an eyeblink attempt. In addition, type of lens fit (interpalpebral vs. lid attachment), lens-to-cornea fit (flat vs. steep), spherical equivalent of the refraction, and corneal coverage (on-eye lens diameter) were analyzed.
Results:
No difference in overall eyeblink frequency was found between nonlens wearers (group I, n = 26), GP lens wearers with less than grade 1 corneal staining (group II, n = 25) and GP lens wearers with grade 1 or more corneal staining (group III, n = 30). Fewer complete eyeblinks, more incomplete eyeblinks and more eyeblink attempts were seen in group III than in group I or II (p < 0.01, p = 0.03, p < 0.01, respectively). Fewer complete eyeblinks and more eyeblink attempts (p < 0.01 for both) were found in interpalpebral lens fits than in lid attachment fits. Fewer complete eyeblinks (p = 0.02) and more incomplete eyeblinks (p = 0.03) were found with lenses rated as large or optimal in size than with lenses rated as small.
Conclusions:
GP lens wearers experiencing 3- and 9-o'clock staining showed a different eyeblink frequency for individual types of eyeblinks, but not for overall eyeblinks. Fewer complete eyeblinks, more incomplete eyeblinks, and more eyeblink attempts were observed in GP wearers with 3- and 9-o'clock staining compared with wearers with minimal staining and nonwearers. In addition, some individual contact lens variables were associated with more incomplete eyeblinks.
Related Concept Videos
Ophthalmic Drug Delivery Systems
Microbiome of the Eye
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Accessory Structures of the Eye
