Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jul 2, 2026

Laparoscopic Left Lateral Sectionectomy: Guided by the Ligamentum Teres Hepatis and the Umbilical Fissure Vein
03:33

Laparoscopic Left Lateral Sectionectomy: Guided by the Ligamentum Teres Hepatis and the Umbilical Fissure Vein

Published on: September 27, 2024

Liver transection using the LigaSure sealing system.

A Saiura1, J Yamamoto, R Koga

  • 1Department of Gastrointestinal Surgery, Cancer Institute Ariake Hospital, Koto-ku, Tokyo, Japan. saiura-tky@umin.ac.jp

HPB : the Official Journal of the International Hepato Pancreato Biliary Association
|September 6, 2008
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Staging laparoscopy for pancreatic cancer using intraoperative ultrasonography and fluorescence imaging: the SLING trial.

The British journal of surgery·2021
Same author

Regional pancreatoduodenectomy versus standard pancreatoduodenectomy with portal vein resection for pancreatic ductal adenocarcinoma with portal vein invasion.

BJS open·2020
Same author

Possible underestimation of blood loss during laparoscopic hepatectomy.

BJS open·2019
Same author

Risk Factors for and Management of Postpancreatectomy Hepatic Steatosis.

Scandinavian journal of surgery : SJS : official organ for the Finnish Surgical Society and the Scandinavian Surgical Society·2016
Same author

Sinistral portal hypertension after pancreaticoduodenectomy with splenic vein ligation.

The British journal of surgery·2014
Same author

Multicentre analysis of long-term outcome after surgical resection for gastric cancer liver metastases.

The British journal of surgery·2014
Same journal

Surgical outcomes in gallbladder cancer: evidence from the UK nationwide CAPBIL study.

HPB : the official journal of the International Hepato Pancreato Biliary Association·2026
Same journal

Machine learning model offers promising individualized prediction for recurrence-free survival in solitary resectable colorectal liver metastasis: strengths, limitations, and future directions.

HPB : the official journal of the International Hepato Pancreato Biliary Association·2026
Same journal

Selective internal radiotherapy vs transarterial chemoembolization for unresectable hepatocellular carcinoma: a systematic review.

HPB : the official journal of the International Hepato Pancreato Biliary Association·2026
Same journal

The impact of operative timing on major post-operative complications following liver transplantation: a retrospective cohort study.

HPB : the official journal of the International Hepato Pancreato Biliary Association·2026
Same journal

Pancreatic resection for metastatic renal cell carcinoma: outcomes in the era of immunotherapy and targeted therapy.

HPB : the official journal of the International Hepato Pancreato Biliary Association·2026
Same journal

Minimally Invasive Versus Open Surgery for Insulinoma: A 20-Year Institutional Experience.

HPB : the official journal of the International Hepato Pancreato Biliary Association·2026
See all related articles

The LigaSure vessel sealing system is safe and effective for liver resections in a large patient cohort. Outcomes were similar in patients with and without liver injury, demonstrating broad applicability.

Area of Science:

  • Hepatobiliary Surgery
  • Surgical Technology
  • Minimally Invasive Procedures

Background:

  • Liver resections are complex procedures requiring effective hemostasis.
  • The LigaSure vessel sealing system offers an alternative for tissue sealing during surgery.

Purpose of the Study:

  • To assess the feasibility and efficacy of the LigaSure system in large-scale liver resections.
  • To evaluate the safety and outcomes associated with LigaSure use in hepatectomy.

Main Methods:

  • Retrospective analysis of 277 patients undergoing hepatectomy.
  • Evaluation of short-term outcomes including blood loss, transection speed, and complications.

Main Results:

  • Low hospital mortality (0.7%) and morbidity rate (25.3%).
Keywords:
LigaSureblood lossliver resection

More Related Videos

Modified Laparoscopic Anatomic Hepatectomy: Two-Surgeon Technique Combined with the Simple Extracorporeal Pringle Maneuver
12:27

Modified Laparoscopic Anatomic Hepatectomy: Two-Surgeon Technique Combined with the Simple Extracorporeal Pringle Maneuver

Published on: June 16, 2023

Laparoscopic Anatomical Liver Segment VII Resection with Liver Parenchymal Transection Following a Priority Approach
13:57

Laparoscopic Anatomical Liver Segment VII Resection with Liver Parenchymal Transection Following a Priority Approach

Published on: May 23, 2025

Related Experiment Videos

Last Updated: Jul 2, 2026

Laparoscopic Left Lateral Sectionectomy: Guided by the Ligamentum Teres Hepatis and the Umbilical Fissure Vein
03:33

Laparoscopic Left Lateral Sectionectomy: Guided by the Ligamentum Teres Hepatis and the Umbilical Fissure Vein

Published on: September 27, 2024

Modified Laparoscopic Anatomic Hepatectomy: Two-Surgeon Technique Combined with the Simple Extracorporeal Pringle Maneuver
12:27

Modified Laparoscopic Anatomic Hepatectomy: Two-Surgeon Technique Combined with the Simple Extracorporeal Pringle Maneuver

Published on: June 16, 2023

Laparoscopic Anatomical Liver Segment VII Resection with Liver Parenchymal Transection Following a Priority Approach
13:57

Laparoscopic Anatomical Liver Segment VII Resection with Liver Parenchymal Transection Following a Priority Approach

Published on: May 23, 2025

  • Mean blood loss: 352+/-422 ml; liver transection speed: 1.9+/-0.86 cm²/min.
  • Similar outcomes in patients with and without liver injury; faster transection in normal livers.
  • Conclusions:

    • The LigaSure system is a safe option for liver resection.
    • Its application is effective irrespective of the presence of liver cirrhosis or injury.
    • The system demonstrates consistent performance across diverse patient liver conditions.