Related Experiment Video
Updated: Aug 17, 2026

Technique of Subnormothermic Ex Vivo Liver Perfusion for the Storage, Assessment, and Repair of Marginal Liver Grafts
Published on: August 13, 2014
A comparison of standard and rapid infusion methods of liver preservation during multi-organ procurement
C Christophi1, B Morgan, I McInnes
1Monash University Department of Surgery, Alfred Hospital, Prahran, Victoria, Australia.
Abstract:
The standard and rapid infusion techniques of liver preservation during multi-organ procurement were compared in the porcine model of orthotopic liver transplantation. Group I (n = 48) had the standard method of procurement while group II (n = 34) underwent the rapid infusion method. Donor liver function was compared between the two methods using the criteria of survival, liver function tests and histology. No statistically significant difference was evident between the two groups. Because of logistical advantages, the rapid infusion method is recommended as the technique of choice during multi-organ procurement.