An electrical muscle stimulation suit for increasing blood pressure
Ulf Balldin1, Lance Annicelli, John Gibbons
1Biosciences and Protection Division, USAF Research Laboratory, Brooks City-Base, TX, USA. ulf.balldin.ctr@brooks.af.mil
Background:
Electrical muscle stimulation (EMS) is used to strengthen muscles in rehabilitation of patients and for training of athletes. Voluntary muscle straining and an inflated anti-G suit increase the arterial blood pressure (BP) and give a pilot G protection during increased +Gz. This study's aim was to measure whether BP also increases with EMS of lower body muscles.
Methods:
A suit with new cloth electrodes sewn into the garment was developed. There were 12 subjects who were tested in sitting position during 3 conditions with 10 consecutive periods of EMS, inflated anti-G suit (GS), or lower body muscle anti-G straining maneuvers (AGSM). BP was continuously measured noninvasively.
Results:
The means of the baseline systolic BP, before each of the test conditions, were 127 +/- 16, 128 +/- 1, and 145 +/- 14 mmHg for GS, AGSM, and EMS, respectively. During inflation of the GS, execution of the AGSM, and EMS, mean systolic BP during the first 10 s was 143 +/- 15, 146 +/- 13, and 150 +/- 13 mmHg, respectively, with no statistical difference between the conditions. The corresponding mean resting heart rate before each test was 57-63 bpm for all conditions. During the test periods with GS, AGSM, and EMS, heart rate was 59 +/- 11, 79 +/- 16, and 61 +/- 15 bpm, respectively, with statistical differences (P < 0.001) between AGSM and the other two conditions.
Conclusion:
EMS created similar BP as GS and AGSM at 1 G and also had higher pre- and post-control values. Further studies are required to evaluate if this principle may be used for G protection of pilots.
Related Concept Videos
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...