Eszopiclone improves overnight polysomnography and continuous positive airway pressure titration: a prospective,
Christopher J Lettieri1, Timothy N Quast, Arn H Eliasson
1Pulmonary and Critical Care Medicine, Walter Reed Army Medical Center, Washington, DC 20307, USA. christopher.lettieri@us.army.mil
Study Objectives:
To assess whether premedication with eszopiclone would improve sleep duration and continuity during polysomnography, thereby improving the quality of diagnostic and CPAP titration studies.
Design:
Prospective, double-blinded, placebo-controlled trial
Setting:
Academic, multidisciplinary sleep center.
Patients:
226 adult subjects undergoing polysomnography for suspected sleep disordered breathing; 113 received eszopiclone and 113 received placebo.
Interventions:
Subjects received eszopiclone 3 mg or matching placebo before polysomnography. We compared sleep latency, efficiency, total sleep time, and apnea-hypopnea index between these groups. We also compared rates of inadequate studies, defined as insufficient sleep time (< 120 min or sleep efficiency < or = 70%) or incomplete CPAP titrations (> or = 5 events/h on the highest CPAP or complete intolerance).
Measurements And Results:
Eszopiclone premedication significantly improved a number of measured variables. Eszopiclone reduced sleep latency (21.7 +/- 27.1 vs. 32.6 +/- 38.2 min, P = 0.014), improved sleep efficiency (87.6% +/- 10.8% vs. 78.1% +/- 15.6%, P < 0.001), reduced wake after sleep onset (39.2 +/- 31.9 vs. 64.5 +/- 45.4 min, P <0.001) and prolonged sleep time (346.5 +/- 53.1 vs. 312.2 +/- 64.2 min, P < 0.001). Sleep efficiencies < or = 70% were more common with placebo than medication (21.2% vs. 7.1%, P = 0.004). Eszopiclone facilitated improved CPAP titrations with fewer residual events (5.7 +/- 10.3 vs. 11.9 +/- 19.6, P = 0.02) and fewer incomplete titrations (31.1% vs. 48.0%, P = 0.04). Poor quality studies (46.0% vs. 26.5%, P = 0.004) were more common with placebo than with eszopiclone. There was a trend for more non-usable studies with placebo (7.1% vs. 2.7%, P = 0.22). Side effects were uncommon and did not differ between groups.
Conclusion:
Pretreatment with eszopiclone improves the quality of polysomnography and CPAP titration and decreases the need to repeat studies. Given the ever-growing demand for polysomnography and the need to improve efficiency, the routine use of nonbenzodiazepines as premedication for polysomnography should be considered.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Sedatives and Hypnotics Drugs: Miscellaneous Agents
Melatonin congeners like ramelteon (Rozerem) and tasimelteon (Hetlioz) selectively bind to melatonin receptors (MT1 and MT2) and thus mimic the actions of melatonin, a hormone that regulates sleep-wake cycles. Tasimelteon is primarily used for non-24-hour sleep-wake disorder, common in blind patients. They are also used to treat conditions like insomnia...
Management of Insomnia
Blind Procedures
COPD: Management Using Bronchodilators and Corticosteroids
Oral Drug Delivery Systems: Continuous-Release Systems