Related Experiment Video
Updated: Jul 1, 2026

Fentanyl Analog Screening using LC-TIMS-TOF MS/MS
Published on: November 8, 2024
Determination of fentanyl in biological and water samples using single-drop liquid-liquid-liquid microextraction
H Ebrahimzadeh1, Y Yamini, A Gholizade
1Department of Chemistry, Shahid Beheshti University, Evin, Tehran, Iran. h-ebrahim@sbu.ac.ir
Abstract:
A single-drop liquid-liquid-liquid microextraction (LLLME) method coupled with high-performance liquid chromatography (HPLC) was developed for the determination of fentanyl in biological (plasma and urine) and wastewater samples. Fentanyl is a potent synthetic narcotic analgesic administered in the form of a transdermal patch for the management of chronic pain. Fentanyl was extracted from 0.01 M NaOH solution (donor phase) into a thin layer of organic phase (100 muL), then back-extracted into 5 muL of the acidic acceptor microdrop (1 x 10(-3)M HClO(4)) immersed in the organic membrane from the tip of a 25-muL HPLC syringe. After the extraction, the microdrop was withdrawn into the syringe and injected directly into a HPLC system for analysis. The parameters influencing the extraction efficiency including the organic solvent and its volume, acceptor microdrop volume, composition of the donor and acceptor phases, stirring rate, temperature, salt addition and pre- and back-extraction times were investigated and optimized. At the most appropriate conditions (100 muL of n-octane, 3.6 mL of the donor phase maintained at 0.01 M NaOH, 5 muL of 1 x 10(-3)M HClO(4) as the acceptor microdrop, stirring rate of 1000 rpm for pre-extraction and 700 rpm for back-extraction, 30 degrees C, no salt addition, 30 min for pre-extraction and 20 min for back-extraction), an enrichment factor (EF) of 355 was obtained. The limit of detection (LOD) was 0.1 ngmL(-1) (based on S/N=3) and intra- and inter-day relative standard deviations less than 9% were obtained. The calibration graph was linear within the range of 0.5-1000 ngmL(-1) with the correlation coefficient (r) of 0.9999. Finally, the feasibility of the proposed method was evaluated by extraction and determination of fentanyl in plasma, urine and wastewater samples and satisfactory results were obtained.
More Related Videos
08:54Determining Four Components in a Lipid Nanoparticle RNA Delivery System by Liquid Chromatography Combined with Evaporative Light Scattering Detector
Published on: May 30, 2025
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: