Related Experiment Video
Updated: Jul 1, 2026

06:59
Intrathecal Application of a Fluorescent Dye for the Identification of Cerebrospinal Fluid Leaks in Cochlear Malformation
Published on: February 29, 2020
Case report: explantation of a cochlear implant secondary to chronic granulating labyrinthitis
Eu-Chin Ho1, Christopher Dunn, David Proops
1Department of Otolaryngology, Queen Elizabeth Hospital, Birmingham B15 2TH, UK.
Cochlear Implants International
|September 16, 2008
Abstract:
In the published series of our first 100 cochlear implants only three developed major complications (Proops et al., 1999). We present a rare case of late granulations forming around a Nucleus cochlear implant, giving rise to erosion of the entire cochlea and adjacent mesotympanum. This pathology has only been reported once in the literature (Bertuleit et al., 1999).