Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose
Paul Stolzmann1, Sebastian Leschka, Hans Scheffel
1Institute of Diagnostic Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich, Switzerland.
Purpose:
To prospectively investigate computed tomographic (CT) image quality parameters by using different protocols and to calculate radiation dose estimates for noninvasive coronary angiography performed with dual-source CT in the step-and-shoot (SAS) mode.
Materials And Methods:
This study was local ethics board approved; written informed consent was obtained from all patients. In the preliminary portion of the study, 40 patients underwent CT coronary angiography in the SAS mode: at 100 kV (protocol A) in 22 patients with a body mass index (BMI) of less than 25 kg/m(2) and at 120 kV (protocol B) in 18 patients with a BMI of 25-30 kg/m(2). Both protocols involved use of an attenuation-based tube current and 1 mL of contrast material per kilogram of body weight. The final portion of the study involved 50 additional patients: 21 patients with a BMI of 25-30 kg/cm(2) assigned to protocol B and 29 patients with a BMI of less than 25 kg/cm(2) assigned to protocol C, which was performed with 100 kV, an attenuation-based tube current, and a reduced contrast material dose of 0.8 mL/kg. Image quality was independently assessed. Attenuation in the aorta and coronary arteries and image noise were measured. Radiation dose was estimated.
Results:
Mean image noise was similar with protocols A and B. Mean attenuation in the aorta and coronary arteries with protocol A (444 HU) was significantly (P < .001) higher than that with protocol B (358 HU). The reduced contrast material dose in protocol C yielded attenuation similar to that with protocol B. Diagnostic image quality was achieved with all protocols in 1237 (97.9%) of 1264 coronary segments. No significant differences in image quality between the 100- and 120-kV protocols were found. Mean heart rate had a significant effect on motion artifacts (area under receiver operating characteristic curve [AUC] = 0.818; 95% confidence interval [CI]: 0.723, 0.892; P < .001), whereas heart rate variability had a significant effect on stair-step artifacts (AUC = 0.79; 95% CI: 0.687, 0.865; P < .001). The mean estimated effective dose was 1.2 mSv +/- 0.2 for protocols A and C and 2.6 mSv +/- 0.5 for protocol B.
Conclusion:
Dual-source SAS-mode CT coronary angiography yielded diagnostic image quality for 97.9% of coronary segments at a low radiation dose.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Acute Coronary Syndrome III: Diagnostic Studies