Abdomen: angiography with 16-detector CT--comparison of image quality and radiation dose between studies with
Toshiharu Miyoshi1, Masayuki Kanematsu, Hiroshi Kondo
1Radiology Services, Gifu University Hospital, 1-1 Yanagido, 501-1194 Gifu, Japan.
Purpose:
To prospectively compare image quality and volume computed tomographic (CT) dose index (CTDI(vol)) of 16-detector CT angiograms of the abdomen acquired with 0.625-mm collimation with those of images acquired with 1.25-mm collimation.
Materials And Methods:
This study had institutional review board approval, and informed consent was obtained from all patients. Dual-phase contrast material-enhanced CT was performed in 78 patients (48 men and 30 women; age, 34-91 years; mean age, 64.8 years) by using a 16-detector CT scanner. Patients were prospectively randomized into two equal-sized groups: those who underwent CT with 0.625-mm collimation and nonoverlapped reconstruction and those who underwent CT with 1.25-mm collimation and 50% overlapped reconstruction. Scan acquisition time was 7.5 seconds in both groups. CTDI(vol) was recorded. Arterial phase volume-rendered, arterial phase multiplanar reformatted, and portal venous phase multiplanar reformatted CT angiograms were generated. Qualitative assessment was performed for image quality and for depiction of splanchnic, intercostal, and lumbar arteries and veins. The unpaired t test was used for statistical comparison.
Results:
On the arterial phase CT angiograms, there was no difference between the two collimation groups for the depiction of proximal splanchnic arteries, while the dorsal pancreatic, intercostal, and lumbar arteries and some peripheral splanchnic arterial branches were better delineated on CT scans obtained with 0.625-mm collimation than on scans obtained with 1.25-mm collimation (P < .05). Regarding the portal venous phase CT angiograms, no difference between the two groups was found in most veins, except the right adrenal vein (P = .003). Image quality was superior for 1.25-mm collimation (P < .001). CTDI(vol) values were positively correlated with patient body weight (r = 0.34, P < .001) but had no correlation with collimation size (P = .24).
Conclusion:
Scanning with 1.25-mm collimation seems adequate for a routine CT angiography examination of most arteries and veins at 16-detector CT, while scanning with 0.625-mm collimation facilitates improved delineation of fine vessels. CTDI(vol) values correlate positively with body weight but have no correlation with collimation size.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT