Related Experiment Video
Updated: Feb 8, 2026

Hand-held Clinical Photoacoustic Imaging System for Real-time Non-invasive Small Animal Imaging
Published on: October 16, 2017
Effects of muscle group and placement site on reliability of hand-held dynamometry strength measurements
Abstract:
Studies of measuring muscle strength with hand-held dynamometers have produced a variety of results. The purpose of this research was to further investigate the effect of muscle group and placement site on reliability. The purpose of Part I of this study was to examine reliabilities of force measurements generated by four specific muscle groups using a hand-held dynamometer (HHD). Part II's purpose was to determine the effects of HHD placement site on the variability of HHD force measurements. In Part I, two testers obtained measurements of right shoulder abductor, wrist extensor, hip flexor, and ankle dorsiflexor forces in 20 subjects. Two-way analysis of variance indicated a main effect due to tester, but no tester by session interaction and no main effect due to session (p < 0.5). Intraclass correlation coefficients ranged from .76-.93 for within-session, intratester reliabilities, .67-.84, for between-session intratester reliabilities, and .30-.83 for within-session, intertester reliabilities. Reliability tended to be higher when HHD placement sites were farther from joint centers. Part II explored the hypothesis that HHD forces would be less variable if measured distally. One tester measured shoulder abductor forces for 30 subjects at three sites on the upper extremity. Bartlett's Test for homogeneity of variance indicated a lower variability at the distal placement site (p < 0.05). J Orthop Sports Phys Ther 1992;15(5):236-242.
Related Concept Videos
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...
Ionic Strength: Effects on Chemical Equilibria
In this solution, the primary...
Reliability and Validity
Skeletal Muscle Relaxants: Adverse Effects
Unlike...
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
The Equilibrium Binding Constant and Binding Strength

