Characterization and utilization of a novel triflate ionic liquid stationary phase for use in comprehensive
Vanessa R Reid1, Jeffery A Crank, Daniel W Armstrong
1Department of Chemistry, University of Washington, Seattle, WA 98195-1700, USA.
Abstract:
A novel triflate (trifluoromethylsulfonate) ionic liquid (IL) thin film (0.08 microm) stationary phase was implemented for use within the second column of a comprehensive GC x GC configuration. The first column in the configuration had a 5% phenyl/95% dimethyl polysiloxane (DMPS) stationary phase with a 0.4 microm film. The DMPS x IL column configuration was used to separate a mixture of 32 compounds of various chemical functional classes. The GC x GC results for the IL column were compared with a commercially available polar column (with a 0.1 microm PEG stationary phase film) used as the second column instead. Additional studies focused on the rapid and selective separation of four phosphorous-oxygen (P-O) containing compounds from the 32-compound matrix: dimethyl methylphosphonate (DMMP), diethyl methylphosphonate (DEMP), diisopropyl methylphosphonate (DIMP), and triethyl phosphate (TEP). van't Hoff plots (plots of ln k vs. 1/T) demonstrated the difference in retention between the P-O containing compounds (with DMMP reported in detail) and other classes of compounds (i. e., 2-pentanol and n-dodecane as representative) using either the IL column or the commercial PEG column. The selectivity (alpha) of the triflate IL column and the commercially available PEG column were also compared. The IL column provided significantly larger selectivities between DMMP and the other two compounds (2-pentanol and n-dodecane) than the commercial PEG column. The alpha for DMMP relative to n-dodecane was 3.0-fold greater for the triflate IL column, and the alpha for DMMP relative to 2-pentanol was 1.7-fold greater for the triflate IL column than for the PEG column.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...


