Thermoforming of tracheal cartilage: viability, shape change, and mechanical behavior
Yongseok Chae1, Dmitriy Protsenko, Paul K Holden
1The Beckman Laser Institute, 1002 Health Sciences Rd East, Irvine, California 92697, USA. ychae@uci.edu
Background And Objectives:
Trauma, emergent tracheostomy, and prolonged intubation are common causes of severe deformation and narrowing of the trachea. Laser technology may be used to reshape tracheal cartilage using minimally invasive methods. The objectives of this study were to determine: (1) the dependence of tracheal cartilage shape change on temperature and laser dosimetry using heated saline bath immersion and laser irradiation, respectively, (2) the effect of temperature on the mechanical behavior of cartilage, and (3) tissue viability as a function of laser dosimetry.
Materials And Methods:
Ex vivo rabbit trachea cartilage specimens were bent and secured around a cylinder (6 mm), and then immersed in a saline bath (45 and 72 degrees C) for 5-100 seconds. In separate experiments, tracheal specimens were irradiated with a diode laser (lambda = 1.45 microm, 220-400 J/cm(2)). Mechanical analysis was then used to determine the elastic modulus in tension after irradiation. Fluorescent viability assays combined with laser scanning confocal microscopy (LSCM) were employed to image and identify thermal injury regions.
Results:
Shape change transition zones, between 62 and 66 degrees C in the saline heating bath and above power densities of 350 J/cm(2) (peak temperatures 65+/-10 degrees C) for laser irradiation were identified. Above these zones, the elastic moduli were higher (8.2+/-4 MPa) than at lower temperatures (4.5+/-3 MPa). LSCM identified significant loss of viable chondrocytes within the laser-irradiation zones.
Conclusion:
Our results indicate a change in mechanical properties occurs with laser irradiation and further demonstrates that significant thermal damage is concurrent with clinically relevant shape change in the elastic cartilage tissues of the rabbit trachea using the present laser and dosimetry parameters.
Related Concept Videos
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of the...
Growth of Cartilage and Bone Tissue
Thermal Strain
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used to...