Related Experiment Video
Updated: Jun 30, 2026

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry (UPLC-MS)
Published on: March 14, 2013
Quantification of small molecules in plasma with direct analysis in real time tandem mass spectrometry, without
Yeping Zhao1, Michelle Lam, Danlin Wu
1Department of Drug Metabolism and Pharmacokinetics, Roche Palo Alto, LLC, 3431 Hillview Ave., Palo Alto, CA 94304, USA. yeping.zhao@roche.com
Abstract:
Recently, a new ion source, Direct Analysis in Real Time (DART), has been introduced which allows direct biological sample introduction into a mass spectrometry (MS) system. The elimination of conventionally required sample preparation and separation by high-performance liquid chromatography (HPLC) prior to MS analysis represents a remarkable opportunity to reduce assay turn-around time, environmental impact and capital/manpower investment. This new technology initially was used in various qualitative applications to directly detect chemicals on solid surfaces, in liquids and gases. In this study, a DART source operating under ambient pressure with ground potential was installed onto a Sciex 4000 tandem mass spectrometer and employed in the sample analysis of plasma based on direct introduction into the DART-MS/MS system. Reasonable precision and accuracy (%CV and %Error, both <10%) were achieved of a significant number of compounds tested in biological fluids. In addition, the limit of detection for 80% of the tested compounds reached 5 ng/mL or lower which is sufficient for pharmaceutical drug discovery support. Finally, experimental conditions that significantly impacted assay performance were investigated with respect to optimization and limitation. Because of its simplicity, fast data acquisition (3-5 s) and low cost, DART has the potential to significantly impact quantitative pharmaceutical analysis in biological matrices.
More Related Videos
12:11Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
11:09An HS-MRM Assay for the Quantification of Host-cell Proteins in Protein Biopharmaceuticals by Liquid Chromatography Ion Mobility QTOF Mass Spectrometry
Published on: April 17, 2018
Related Concept Videos
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry
High-Performance Liquid Chromatography: Types of Detectors