[Optimization of the scan delay time of 64-slice spiral CT portal venography]
Cheng-wei Guo1, Wen Liang, Xian-yue Quan
1Department of Radiology, Zhujiang Hospital, Southern Medical University, Guangzhou, China. gcw66157@163.com
Objective:
To optimize scan delay time of multi-slice spiral CT portal venography (MSCTP) using test bolus injection.
Methods:
Sixty individuals with no hepatic diseases were randomly divided into 4 groups (A, B, C and D). The time-density curves (TDC) of the portal vein (PV) were acquired by test bolus (15 ml, 5 ml/s) at the level of liver hilus. In the 4 groups, the MSCTP were delayed for 4, 6, 8 and 10 s according to the peak time of TDC, respectively. The maximum CT value of the portal vein and liver parenchyma were recorded. The maximum intensity projection (MIP) and volume rendering (VR) were employed for three-dimensional reconstruction and the image quality of the 4 groups was estimated.
Results:
The average peak time of healthy individuals ranged between 24 and 32 s (95% confidence interval) by means of the test bolus (15 ml). Group C (delay time of 8 s) had a much better image quality of the portal vain than the other groups, and the small branches of the portal vein (6th and 7th orders) were clearly visualized; the major portal vein branches (1st to 4th orders) were also enhanced with sharp edges. Although the hepatic vein was also observed in the portal venous phase in group D, the details of the portal vein on the hepatic edge were distinct and well defined.
Conclusion:
At the injection rate of 5 ml/s, the optimum scan time delayed is 8 to 10 s in normal individuals according to the peak time of the test bolus.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...