Related Experiment Video
Updated: Jun 29, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
A comprehensive comparison of the continual reassessment method to the standard 3 + 3 dose escalation scheme in Phase
Alexia Iasonos1, Andrew S Wilton, Elyn R Riedel
1Department of Epidemiology and Biostatistics, Memorial Sloan Kettering Cancer Center, New York, NY 10021, USA. iasonosa@mskcc.org
Background:
An extensive literature has covered the statistical properties of the Continual Reassessment Method (CRM) and the modifications of this method. While there are some applications of CRM designs in recent Phase I trials, the standard method (SM) of escalating doses after three patients with an option for an additional three patients SM remains very popular, mainly due to its simplicity. From a practical perspective, clinicians are interested in designs that can estimate the MTD using fewer patients for a fixed number of doses, or can test more dose levels for a given sample size.
Purpose:
This article compares CRM-based methods with the SM in terms of the number of patients needed to reach the MTD, total sample size required, and trial duration.
Methods:
The comparisons are performed under two alternative schemes: a fixed or a varying sample approach with the implementation of a stopping rule. The stopping rule halts the trial if the confidence interval around the MTD is within a pre-specified bound. Our simulations evaluated several CRM-based methods under different scenarios by varying the number of dose levels from five to eight and the location of the true MTD.
Results:
CRM and SM are comparable in terms of how fast they reach the MTD and the total sample size required when testing a limited number of dose levels (
Limitations:
We focused on methods with practical design features that are of interest to clinicians. However, there are several alternative CRM-based designs that are not investigated in this manuscript, and hence our results are not generalizable to other designs.
Conclusions:
We show that CRM-based methods are an improvement over the SM in terms of accuracy and optimal dose allocation in almost all cases, except when the true dose is among the lower levels.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
Related Concept Videos
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Dosage Regimen: Individualization
Dose Size and Dosing Frequency: Determination Methods
Dose Response Curve: Conventional Versus Nonmonotonic
Dosage Regimens: Designs and Approaches
IV Infusion to Oral Dosing: Conversion Methods