Intertester reliability of brachial artery flow-mediated vasodilation using upper and lower arm occlusion in healthy

Ludmila M Cosio-Lima1, Richard Seip, Paul D Thompson

  • 1University of West Florida, Pensacola, FL 32514, USA. lcosiolima@uwf.edu

The assessment of endothelial function as brachial artery flow-mediated vasodilatation is a widely used technique that determines the effect of risk factor intervention and may have the potential to predict the clinical benefit of antiatherogenic therapy. Previous studies suggest that flow-mediated dilation is greater using the upper-arm occlusion technique, but no data are available to compare intertester reliability between technicians. This study was undertaken to compare the amount of hyperemia between upper and lower occlusion techniques and to determine reproducibility between testers. Nineteen healthy adults, ages 25 to 50, were included in the study. Brachial artery vasodilatation was measured 1 and 3 minutes post cuff deflation and was compared with the baseline and expressed as a percent change. There was a tester effect in the percent change in diameter across all measurements. The results of this study reveal inconsistencies between testers when using a blood pressure cuff to induce hyperemia for the assessment of endothelial function through brachial artery flow-mediated vasodilation. However, upper arm as compared to lower arm blood pressure cuff occlusion results in significantly greater hyperemia and vasodilatation, even though there was a difference in measurements between testers.

Related Concept Videos

Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Sites for measuring blood pressure01:21

Sites for measuring blood pressure

Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure01:10

Pre-Procedural Guidelines for Assessing Blood Pressure

Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the patient.