Related Experiment Video
Updated: Jun 29, 2026

Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Intertester reliability of brachial artery flow-mediated vasodilation using upper and lower arm occlusion in healthy
Ludmila M Cosio-Lima1, Richard Seip, Paul D Thompson
1University of West Florida, Pensacola, FL 32514, USA. lcosiolima@uwf.edu
The assessment of endothelial function as brachial artery flow-mediated vasodilatation is a widely used technique that determines the effect of risk factor intervention and may have the potential to predict the clinical benefit of antiatherogenic therapy. Previous studies suggest that flow-mediated dilation is greater using the upper-arm occlusion technique, but no data are available to compare intertester reliability between technicians. This study was undertaken to compare the amount of hyperemia between upper and lower occlusion techniques and to determine reproducibility between testers. Nineteen healthy adults, ages 25 to 50, were included in the study. Brachial artery vasodilatation was measured 1 and 3 minutes post cuff deflation and was compared with the baseline and expressed as a percent change. There was a tester effect in the percent change in diameter across all measurements. The results of this study reveal inconsistencies between testers when using a blood pressure cuff to induce hyperemia for the assessment of endothelial function through brachial artery flow-mediated vasodilation. However, upper arm as compared to lower arm blood pressure cuff occlusion results in significantly greater hyperemia and vasodilatation, even though there was a difference in measurements between testers.
The assessment of endothelial function as brachial artery flow-mediated vasodilatation is a widely used technique that determines the effect of risk factor intervention and may have the potential to predict the clinical benefit of antiatherogenic therapy. Previous studies suggest that flow-mediated dilation is greater using the upper-arm occlusion technique, but no data are available to compare intertester reliability between technicians. This study was undertaken to compare the amount of hyperemia between upper and lower occlusion techniques and to determine reproducibility between testers. Nineteen healthy adults, ages 25 to 50, were included in the study. Brachial artery vasodilatation was measured 1 and 3 minutes post cuff deflation and was compared with the baseline and expressed as a percent change. There was a tester effect in the percent change in diameter across all measurements. The results of this study reveal inconsistencies between testers when using a blood pressure cuff to induce hyperemia for the assessment of endothelial function through brachial artery flow-mediated vasodilation. However, upper arm as compared to lower arm blood pressure cuff occlusion results in significantly greater hyperemia and vasodilatation, even though there was a difference in measurements between testers.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.