Related Experiment Video
Updated: Jun 29, 2026

Studying Murine Small Bowel Mechanosensing of Luminal Particulates
Published on: March 18, 2022
Narrow band imaging with magnification for the characterization of small and diminutive colonic polyps: pit pattern
J E East1, N Suzuki, P Bassett
1Wolfson Unit for Endoscopy, St Mark's Hospital, Imperial College London, London, UK. jameseast6@yahoo.com
Background And Study Aims:
Narrow band imaging (NBI) can accurately characterize colonic polyps using microvascular appearances. We aimed to assess whether the Kudo pit pattern classification is accurate when used with NBI (without dye-spray), and if microvascular appearances or NBI pit patterns maintain accuracy for polyp characterization at sizes < 10 mm.
Patients And Methods:
116 polyps < 10 mm in size were detected in 62 patients undergoing surveillance colonoscopy. The polyps were prospectively assessed using NBI and magnification for Kudo pit pattern (III-V neoplastic, I-II non-neoplastic) and vascular pattern intensity (VPI), a measure of microvascular density (strong VPI, neoplastic; normal or weak VPI, non-neoplastic). Sensitivity, specificity, and accuracy were calculated and compared with results from histopathology.
Results:
The mean polyp size was 3.4 mm (range 1 - 9 mm). Overall, NBI pit pattern sensitivity, specificity, and accuracy were 0.88, 0.91, and 89.6 %, respectively. Equivalent values for VPI were 0.94, 0.89, and 91.4 %. Results were similar when polyps were subdivided into diminutive polyps (size
Conclusion:
The NBI pit pattern and VPI are both highly accurate in characterizing neoplastic colonic polyps of < 10 mm, with VPI appearing to be simple to learn. NBI has the potential to replace conventional histology for small polyps.