Through-the-Wall Blood Sampling Method to Minimize Sleep Disruption in Clinical Settings
Published on: June 13, 2025
[Clearances in automated intermittent peritoneal techniques: a new formula to use morning blood sampling]
M Napoli1, A De Pascalis, F Russo
1U.O. Nefrologia, Dialisi, Trapianto, S.O. V. Fazzi, Piazza F. Muratore 1, Lecce, Italy. marcellonapoli@hotmail.com
Abstract:
According to the main guidelines, dialysis adequacy monitoring is fundamental in the management of patients on peritoneal dialysis. In order to avoid mistakes in the calculation of the peritoneal urea and creatinine clearance in patients on dialysis with intermittent techniques, the collection of blood samples about 6 hours after the end of the dialysis session is advised. In fact, because the creatinine and urea values at the end of dialysis (the morning values in NIPD) are the lowest, the resulting clearances could be overestimated. The mean values between the start and the end of the dialysis session are considered the gold standard. However, collecting a blood sample at 2.00 p.m. may be difficult and uncomfortable both for the nurse and the patient. In this paper we present two formulas (the first for urea and the second for creatinine) which, starting from the values at the end of dialysis, predict the values at the beginning of the session and consequently the mean values. The aim of this study was to validate the formulas by evaluating their capability to predict the mean urea and creatinine values when only end-of-dialysis blood sampling was performed. Statistical analysis was carried out using the Bland-Altman test. The two formulas proved able to predict the mean urea and creatinine values; the differences between the measured and calculated values were not statistically significant.
More Related Videos
14:54An In Vivo Method for Evaluating the Gut-Blood Barrier and Liver Metabolism of Microbiota Products
Published on: October 20, 2018
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Peritoneal Dialysis I: Introduction and Procedure
Pre-Procedural Guidelines for Assessing Blood Pressure