Related Experiment Video
Updated: Jun 29, 2026

11:51
An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Bone level changes at implants supporting crowns or fixed partial dentures with or without cantilevers
Gian Andrea Hälg1, Jürg Schmid, Christoph H F Hämmerle
1Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Dental School, University of Zurich, Zurich, Switzerland. gianni.haelg@zzmk.uzh.ch
Clinical Oral Implants Research
|October 3, 2008
Summary
Cantilever extensions on implant-supported fixed dental prostheses (FDPs) did not increase peri-implant bone loss or implant failure rates. However, cantilever FDPs were associated with a higher incidence of technical complications compared to non-cantilever designs.
Area of Science:
- Dentistry
- Prosthodontics
- Implantology
Background:
- Fixed dental prostheses (FDPs) are commonly used to restore partially dentate patients.
- Cantilever extensions on FDPs may influence biomechanical forces on supporting implants.
- Understanding the impact of cantilevers on peri-implant bone health and prosthesis survival is crucial.
Purpose of the Study:
- To evaluate if cantilever extensions on implant-supported FDPs lead to increased peri-implant bone loss.
- To compare technical complication rates between FDPs with and without cantilevers.
- To assess implant survival rates in relation to cantilever use.
Main Methods:
- A comparative study involving 54 patients with 54 implant-supported FDPs (27 cantilever, 27 control).
- Peri-implant marginal bone level changes were measured over a mean follow-up of 5.3 years.
- Implant survival rates and technical complications were assessed using statistical analyses.
Main Results:
- Mean peri-implant bone loss was 0.23 mm for cantilever FDPs and 0.09 mm for non-cantilever FDPs, with no statistically significant difference.
- Implant survival rates were high in both groups (95.7% cantilever, 96.9% control).
- Minor technical complications occurred in 5 cantilever FDPs, but none in the control group.
Conclusions:
- Cantilever extensions on implant-supported FDPs do not significantly increase peri-implant bone loss or implant failure.
- FDPs with cantilever designs showed a higher rate of technical complications.
- Clinical decisions regarding cantilever use should consider the potential for increased technical issues.