Central venous oxygen saturation cannot replace mixed venous saturation in patients undergoing cardiac surgery
Anne-Grethe Lorentzen1, Christian Lindskov, Erik Sloth
1Department of Anesthesia and Intensive Care, Aarhus University Hospital-Skejby, Aarhus, Denmark.
Objective:
It has been argued that venous oxygen saturation from a central venous catheter (ScvO(2)) could be an inexpensive alternative to mixed venous oxygen saturation (SvO(2)). The aim was to evaluate whether ScvO(2) measurements could replace SvO(2) readings after cardiac surgery and to analyze factors influencing any differences found.
Design:
A prospective observational study.
Setting:
A university hospital.
Participants:
Twenty patients scheduled for elective cardiac surgery.
Interventions:
Patients were followed postoperatively with corresponding ScvO(2)/SvO(2) measurements.
Measurements And Main Results:
The overall bias between ScvO(2) and SvO(2) was 1.9. In coronary artery bypass graft (CABG) patients, the bias was 0.6 compared with 6.4 in procedures involving aortic valve replacement. In situations with peripheral saturation (SAT) <92%, the bias was 10.7 compared with 0.8 when SAT was >or=99%. In 25.5% of measurements, the ScvO(2) was more than 10% different from SvO(2), and in only 50% the difference was less than 5%.
Conclusions:
The ScvO(2) and SvO(2) measurements are not interchangeable, and, especially in patients undergoing aortic valve surgery, this lack of agreement is crucial. However, the present data indicate that ScvO(2) may be used in CABG patients, although it is not completely accurate in terms of absolute venous saturations. A low SAT, low hemoglobin, or low cardiac index increased the venous gap.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...