Related Experiment Video
Updated: Jun 29, 2026

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh
Published on: May 3, 2019
[Laser-induced isotopic discrimination effect in laser resonance ionization process of lead atom]
Xin-Shun Wang1, Ying Li, Lin Dai
1Optics & Optoelectronics Laboratory, Ocean University of China, Qingdao 266071, China.
Abstract:
Isotope ratio measurements have been increasingly used in geochemistry, geochronology, cosmos chemistry and environmental science. Precise and accurate isotope ratio measurements are an important task in many applications such as the determination of isotope variations in geological and cosmic samples. Due to its high sensitivity, high ionization efficiency and high element selectivity, laser resonance ionization spectroscopy has nowadays become one of the key techniques, including isotope ratio measurements and trace amount analyses. Because of the isotope shifts and hyperfine structure, there is laser-induced isotopic discrimination effect in the process of laser resonance ionization. The different isotope ionization efficiency can affect precise and accurate measurement of isotope ratios. In the present paper, the dependences of the laser-induced isotopic discrimination effect on some of the laser parameters were studied by theoretical methods. Based on the numerical simulation of the population rate equations, laser-induced isotopic discrimination effect of lead isotopes was studied, by calculating laser resonance ionization transition "6s2 6p23 P0-6s2 6p7 s3 P1(0) --> ionization". The population rate equations was approximated considering some factors which affect the probability of laser resonance transition such as spectral lines width of laser and atom, isotope shifts and hyperfine structure. According to the approximated population rate equations, "1+1" laser resonant ionization process was employed to calculate the ionization probability of lead isotopes by means of computer simulation. The dependences of laser-induced isotopic discrimination effect on the laser parameters, such as laser central wavelength, bandwidth and intensity were investigated. The calculated results show that the laser-induced isotopic discrimination effect of lead isotopes could be almost eliminated by operating at optimized wavelength and could be lessened by using wide band laser. Saturated ionization of lead isotopes was achieved by using a high intensity laser, consequently the laser-induced isotopic discrimination effect of lead isotopes could be eliminated.
More Related Videos
08:53Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
09:05Imaging Metals in Brain Tissue by Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry (LA-ICP-MS)
Published on: January 22, 2017
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Mass Spectrometry: Isotope Effect
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Atomic Emission Spectroscopy: Interference