Related Experiment Video
Updated: Jun 29, 2026

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Postoperative chest tube management: measuring air leak using an electronic device decreases variability in the
Gonzalo Varela1, Marcelo F Jiménez, Nuria Maria Novoa
1Service of Thoracic Surgery, Salamanca University Hospital, 37007 Salamanca, Spain.
Objectives:
Since there are no data in the literature regarding variability in the management of postoperative pleural drainages, we have designed a prospective randomized study aimed at measuring inter-observer variability in deciding when to withdraw chest tubes after lung resection and to evaluate if the use of an electronic device to measure postoperative air leak decreases clinical practice variations.
Methods:
Sixty-one patients undergoing pulmonary resection were randomly assigned to one of the following groups: digital group (electronic measure of pleural air leak using Millicore AB DigiVent chest drainage system) or traditional group (standard water seal pleural chamber). Chest tube withdrawal criteria were established in advance. During morning rounds, two thoracic surgeons with comparable clinical experience and blinded to the decision of their counterpart, evaluated chest tube withdrawal criteria and noted whether the tube should be withdrawn or not. Inter-observer variability kappa index and global, positive, and negative agreement rates were calculated on 2 x 2 tables. Each observation episode was considered in the calculation.
Results:
Fifty-four observations were recorded in the traditional group. Kappa coefficient was 0.37 (overall agreement rate: 0.58; positive agreement rate: 0.72; and negative agreement rate: 0.64). In the digital group, 67 observations were recorded. Kappa coefficient was 0.88 (overall agreement rate: 0.94; positive agreement rate 0.94; and negative agreement rate 0.94).
Conclusions:
We have demonstrated a high rate of disagreement related to the indication to remove chest tubes after lung resection and the improvement of the agreement rate with the use of an electronic device to measure postoperative air leak and pleural pressures.
Related Concept Videos
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Pneumothorax-II
Clinical Manifestations:
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...