Related Experiment Video
Updated: Jun 29, 2026

Activated Cross-linked Agarose for the Rapid Development of Affinity Chromatography Resins - Antibody Capture as a Case Study
Published on: August 16, 2019
MEP chromatography of antibody and Fc-fusion protein using aqueous arginine solution
Tsutomu Arakawa1, Yoshiko Kita, Haruna Sato
1Alliance Protein Laboratories, Inc., 3957 Corte Cancion, Thousand Oaks, CA 91360-6919, USA. tarakawa2@aol.com
Abstract:
MEP HyperCel resin, one of the Protein-A mimetic columns, is designed to bind antibodies at physiological pH and elutes the bound antibodies at mildly acidic pH. We have tested aqueous arginine solution for washing and elution of the resin. To our surprise, bound antibody and Fc-fusion protein eluted at pH 7.0 using 1M arginine solution. Various solvent additives were then examined at pH 7.0. Among the tested additives, urea and arginine were the only additives that were effective in elution. Thus, urea and arginine at low concentrations were effectively used for washing the resin. NaCl and MgCl(2) at 0.1-1M and ethanol at 5-20% were not effective. Based on these observations, it appears that protein binds to MEP resin through both polar and hydrophobic interactions with some contribution of electrostatic interaction, which can be simultaneously reduced by arginine or urea. On the other hand, Mabsorbent, another Protein-A mimetic column, appears to be more non-specific and non-selective.