Matrix-isolated diglycolic anhydride: vibrational spectra and photochemical reactivity

S Jarmelo1, I D Reva, L Lapinski

  • 1Department of Chemistry, University of Coimbra, 3004-535 Coimbra, Portugal. sjarmelo@qui.uc.pt

Related Concept Videos

IR and UV–Vis Spectroscopy of Aldehydes and Ketones01:29

IR and UV–Vis Spectroscopy of Aldehydes and Ketones

Infrared spectroscopy, also known as vibrational spectroscopy, is mainly used to determine the types of bonds and functional groups in molecules. In aldehydes and ketones, the carbonyl (C=O) bond shows an absorption around 1710 cm-1. The C=O bond vibration of an aldehyde occurs at lower frequencies than that of a ketone. In addition to the C=O absorption in an aldehyde, the aldehydic C–H bond also gives two peaks in the 2700–2800 cm-1 range. This absorption, coupled with the C=O stretching, is...
NMR Spectroscopy and Mass Spectrometry of Aldehydes and Ketones01:15

NMR Spectroscopy and Mass Spectrometry of Aldehydes and Ketones

In aldehydes, the hydrogen atom connected to the carbonyl carbon helps distinguish aldehydes from other carbonyl compounds using ¹H NMR spectroscopy. The closeness of aldehydic hydrogen to the electrophilic carbonyl carbon highly deshields the hydrogen atom causing its signal to appear around 10 ppm in the ¹H NMR spectra. α hydrogens split the aldehydic proton signal, which helps identify the number of α hydrogens in the molecule. For instance, one α hydrogen creates a doublet for an aldehydic...
Spectroscopy of Carboxylic Acid Derivatives01:26

Spectroscopy of Carboxylic Acid Derivatives

Infrared spectroscopy is primarily used to determine the types of bonds and functional groups. In carboxylic acid derivatives, a typical carbonyl bond absorption is observed around 1650–1850 cm−1. For esters, the absorption is recorded at around 1740 cm−1, while acid halides show the absorption at about 1800 cm−1. Another acid derivative, the acid anhydrides, exhibit two carbonyl absorption around 1760 cm−1 and 1820 cm−1, arising from the symmetrical and unsymmetrical carbonyl vibration.
In the...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations01:08

IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations

Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single stretching vibration...
Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation01:01

Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation

The fragmentation patterns observed for compounds such as carboxylic acids, esters, and amides in the mass spectra include ⍺-cleavage and McLafferty rearrangement. Fragmentation by ⍺-cleavage preferentially occurs at the carbon-carbon bond at the ⍺-position next to the carboxylic group to generate a neutral radical and a cation. Long chain compounds with hydrogen at their γ-carbon undergo McLafferty rearrangement to give a radical cation and a neutral alkene.
For example, the fragmentation of...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...