Related Experiment Video
Updated: Jun 29, 2026

Ubiquitin Chain Analysis by Parallel Reaction Monitoring
Published on: June 17, 2020
Rapid comprehensive amino acid analysis by liquid chromatography/tandem mass spectrometry: comparison to cation
Dennis J Dietzen1, Annette L Weindel, Mary O Carayannopoulos
1Department of Pediatrics, Washington University School of Medicine, St. Louis, MO, USA. dietzen_d@kids.wustl.edu
Abstract:
Ion-exchange chromatography with ninhydrin detection remains the gold standard for detecting inborn errors of amino acid catabolism and transport. Disadvantages of such analysis include long chromatography times and interference from other ninhydrin-positive compounds. The aim of this project was to develop a more rapid and specific technique using liquid chromatography/tandem mass spectrometry (LC/MS/MS). Optimal fragmentation patterns for 32 amino acids were determined on a triple quadrupole mass spectrometer following butylation. Chromatographic characteristics of each of the amino acids were determined using C8 reversed-phase chromatography with 20% acetonitrile/0.1% formic acid as isocratic mobile phase. Quantitation using eleven deuterated internal standards was compared to cation exchange and ninhydrin detection on a Beckman 7300 system. Following methanol extraction and butylation, determination of 32 amino acids required 20 min. The dynamic range of each amino acid was generally 1-1000 micromol/L. Imprecision ranged from 7 to 23% (CV) over 6 months and recovery ranged from 88-125%. Deming regression with the Beckman 7300 yielded slopes from 0.4-1.2, intercepts from -21 to 65 micromol/L, correlation coefficients from 0.84-0.99 and Syx from 2-125 micromol/L. Isobaric amino acids were separated by chromatography (e.g. leucine, isoleucine) or by unique fragmentation (e.g., alanine, beta-alanine). LC/MS/MS is comparable to traditional LC-ninhydrin detection. Mass spectral detection shortens analysis times and reduces potential for interference in detecting inborn metabolic errors.
More Related Videos
08:14Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
08:01LERLIC-MS/MS for In-depth Characterization and Quantification of Glutamine and Asparagine Deamidation in Shotgun Proteomics
Published on: April 9, 2017
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Ion-Exchange Chromatography
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry of Amines