Min Zhang1, Yuguang Wu, Kip Hauch
1Department of Bioengineering, University of Washington, Seattle, WA 98195, USA. minz@u.washington.edu
Abstract:
The roles of adsorbed fibrinogen (Fg) and von Willebrand factor (VWF) in mediating platelet adhesion to synthetic surfaces under flow were investigated using polystyrene (PS) as a model hydrophobic surface. We measured platelet adhesion to PS pre-adsorbed with Fg, VWF, normal plasma, afibrinogenemic plasma, VWF-deficient plasma and deficient plasmas with various concentrations of added Fg or VWF. Platelets in a red blood cell suspension were passed through a flow chamber at either low (50 or 100 s(-1)) or high (500 or 1000 s(-1)) shear. Adhesion to PS pre-adsorbed with afibrinogenemic plasma was very low under both low and high shear conditions, but was restored in a dose-dependent manner with addition of Fg. Less than 20 ng/cm(2)of adsorbed Fg was sufficient to support full-scale platelet adhesion under flow. At high shear rate, platelet adhesion on PS pre-adsorbed with VWF-deficient plasma was much less than on PS pre-adsorbed with normal plasma, but adhesion to PS pre-adsorbed with VWF-deficient plasma with added VWF was very similar to adhesion to PS pre-adsorbed with normal plasma. At low shear, adhesion to PS pre-adsorbed with VWF-deficient plasma was the same as on PS pre-adsorbed with normal plasma. As little as 1 ng/cm(2) of VWF adsorbed from plasma made platelet adhesion higher under high shear than under low shear. The effects of adsorbed Fg and VWF on the morphologies of platelets that adhered from suspensions flowing at high shear rates were also investigated. The lack of either Fg or VWF resulted in marked decreases in the extent of platelet spreading. Real-time observation of platelet adhesion under an epifluorescent microscope showed that platelets adhered to the surface in a linear pattern aligned in the direction of flow under high shear conditions.
More Related Videos
Related Concept Videos
Formation of the Platelet Plug
As the injured blood vessel contracts, endothelial cells undergo contraction, revealing collagen fibers in the basement membrane and underlying connective tissue. Furthermore, the plasma membrane of endothelial cells becomes adhesive, preparing the site for platelet adhesion. Platelets...
Intracellular Signaling Affects Focal Adhesions
Some...
Clot Retraction and Fibrinolysis
Structure and Function of Platelets
Platelets are continually replenished, circulating in the bloodstream for 9-12 days before being removed by phagocytes, primarily in the spleen. A microliter of circulating blood contains between 150,000 and 450,000 platelets, with...
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which forms a...
Introduction to Hemostasis
The three phases of hemostasis involve many clotting factors present in plasma and several substances released by platelets and injured tissue cells. It is a fast, localized, and...