The angle-measuring device, a practical resource in high tibial osteotomy.

P J Jokio1, T S Lindholm

  • 1Military Central Hospital, Helsinki, Finland.

Annales Chirurgiae Et Gynaecologiae
|January 1, 1991
PubMed
Summary

High tibial osteotomy for medial gonarthrosis showed measurement errors. An angle-measuring device resulted in greater varus undercorrection compared to caliper measurements for high tibial osteotomy accuracy.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The effect of different mineral frames on ectopic bone formation in mouse hind leg muscles induced by native reindeer bone morphogenetic protein.

Archives of orthopaedic and trauma surgery·2005
Same author

Influence of ethylene oxide sterilization on the activity of native reindeer bone morphogenetic protein.

International orthopaedics·2004
Same author

New bone formation induced by injection of native reindeer bone morphogenetic protein extract.

Scandinavian journal of surgery : SJS : official organ for the Finnish Surgical Society and the Scandinavian Surgical Society·2003
Same author

Bovine bone implant with bovine bone morphogenetic protein in healing a canine ulnar defect.

International orthopaedics·2001
Same author

Composite implant composed of hydroxyapatite and bone morphogenetic protein in the healing of a canine ulnar defect.

Annales chirurgiae et gynaecologiae·2001
Same author

Native bovine bone morphogenetic protein improves the potential of biocoral to heal segmental canine ulnar defects.

International orthopaedics·2001

Area of Science:

  • Orthopedic Surgery
  • Biomechanics
  • Medical Imaging

Background:

  • Medial gonarthrosis, a common cause of knee pain, often requires surgical intervention.
  • High tibial osteotomy (HTO) is a surgical procedure to correct knee alignment and alleviate pain.
  • Accurate correction of knee alignment is crucial for successful HTO outcomes.

Purpose of the Study:

  • To compare the accuracy of two measurement methods during high tibial osteotomy.
  • To evaluate the miscorrection in degrees of varus alignment after HTO.
  • To identify sources of error in HTO surgical techniques.

Main Methods:

  • Thirty-two patients with medial gonarthrosis underwent high tibial osteotomy.
  • Wedge base measurements were taken using calipers in 16 knees.
  • An angle-measuring device was used for measurements in the other 16 knees.

Main Results:

  • Caliper measurement resulted in a miscorrection of 0.2 +/- 4.7 degrees.
  • The angle-measuring device led to a 2.4 +/- 4.1 degrees varus undercorrection.
  • Sources of error include mechanical axis deviation measurement, device accuracy, and surgical technique.

Conclusions:

  • The angle-measuring device is a valuable tool for high tibial osteotomy.
  • Accurate measurement techniques are essential to minimize miscorrection in HTO.
  • Further research into minimizing errors related to knee laxity and age-related overcorrection is warranted.