A prospective study of intraoperative pulse oximetry failure
P R Freund1, P T Overand, J Cooper
1Department of Anesthesiology, University of Washington School of Medicine, Seattle.
Abstract:
Since pulse oximetry is now an ASA standard for intraoperative monitoring, we sought to determine the intraoperative failure rate for this device. We prospectively evaluated the intraoperative failure rate of our pulse oximeters at the four University of Washington Hospitals (University of Washington Medical Center, Veterans Affairs Medical Center [VAMC], Children's Hospital and Medical Center, and Harborview Medical Center [HMC]) recorded from April 1989 to August 1989. We defined failure as the inability to obtain any oximetry reading for a cumulative period of more than 30 minutes during any anesthetic procedure after all equipment malfunctions had been eliminated. Our puse oximeters failed in 124 of 11,046 cases studied; this is a failure rate of 1.12%, which ranged from 0.56% at HMC to 4.24% at VAMC. The failure rate at VAMC (4.24%) was significantly higher than the other hospitals (p less than 0.001). Those cases associated with the pulse oximeter failure had the following characteristics: (1) an ASA status of 3 or higher, (2) lengthy operations, and (3) elderly patients. When the device did fail in a patient, it did not function for 32% of the mean anesthesia time. We conclude that the intraoperative use of the pulse oximetry can provide information about blood oxygen saturation in most patients. However, in approximately 1% of the patients we studied in the operating room, mechanically functioning pulse oximeters failed to provide readings of blood oxygen saturations during routine operative use.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Special considerations while measuring pulse
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...