Aortoiliac dissection after percutaneous insertion of an intra-aortic balloon pump

J C Yuen1, O E Riggs

  • 1Department of Surgery, West Virginia University Medical Center, Morgantown.

Southern Medical Journal
|September 1, 1991
PubMed

Insights

Percutaneous intra-aortic balloon pump insertion can cause aortic dissection, a serious complication. This case highlights unusual bilateral iliac artery stenosis following femoral cannulation for balloon pump placement.

Area of Science:

  • Cardiovascular interventions
  • Vascular surgery
  • Interventional cardiology

Background:

  • Percutaneous intra-aortic balloon pump (IABP) insertion is a critical procedure for hemodynamic support.
  • Aortic and aortoiliac dissections are known, though infrequent, complications of IABP placement.
  • These dissections can lead to severe outcomes, including thrombosis, perforation, and death.

Observation:

  • This case study focuses on a patient undergoing percutaneous femoral cannulation for IABP insertion.
  • The procedure resulted in an aortoiliac dissection.

Findings:

  • The aortoiliac dissection led to bilateral iliac artery stenosis.
  • This specific complication, stenosis secondary to dissection from femoral cannulation for IABP, is unusual.
  • Thrombosis can occur without overt signs of obstruction, complicating diagnosis.

Implications:

  • Awareness of unusual complications like bilateral iliac artery stenosis is crucial for clinicians performing IABP procedures.
  • Early recognition and management of dissection-related complications are vital to prevent adverse events.
  • This case underscores the need for vigilance regarding potential vascular injuries during percutaneous interventions.