Related Concept Videos

Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Confocal and multiphoton microscopy: A selective review.

Journal of microscopy·2026
Same author

Dual-Illumination Fourier Modulation Microscopy: New Techniques for Multimodal Light Imaging.

Microscopy research and technique·2025
Same author

Image scanning microscopy with a doughnut beam: signal strength and integrated intensity.

Journal of the Optical Society of America. A, Optics, image science, and vision·2023
Same author

Advancing full-field metrology: rapid 3D imaging with geometric phase ferroelectric liquid crystal technology in full-field optical coherence microscopy.

Biomedical optics express·2023
Same author

Signal strength and integrated intensity in confocal and image scanning microscopy.

Journal of the Optical Society of America. A, Optics, image science, and vision·2023
Same author

Focus image scanning microscopy for sharp and gentle super-resolved microscopy.

Nature communications·2022

Related Experiment Video

Updated: Jun 28, 2026

Digital Inline Holographic Microscopy (DIHM) of Weakly-scattering Subjects
10:16

Digital Inline Holographic Microscopy (DIHM) of Weakly-scattering Subjects

Published on: February 8, 2014

Image formation in holographic tomography.

Shan Shan Kou1, Colin J R Sheppard

  • 1Optical Bioimaging Laboratory, Division of Bioengineering, National University of Singapore, Singapore.

Optics Letters
|October 17, 2008
PubMed
Summary
This summary is machine-generated.

Holographic tomography improves 3D imaging. Rotating the illumination beam offers different performance than rotating the object, impacting spatial frequency coverage and singularity points in 3D reconstructions.

More Related Videos

Uncovering Hidden Dynamics of Natural Photonic Structures Using Holographic Imaging
05:45

Uncovering Hidden Dynamics of Natural Photonic Structures Using Holographic Imaging

Published on: March 31, 2022

Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution
08:41

Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution

Published on: August 16, 2012

Related Experiment Videos

Last Updated: Jun 28, 2026

Digital Inline Holographic Microscopy (DIHM) of Weakly-scattering Subjects
10:16

Digital Inline Holographic Microscopy (DIHM) of Weakly-scattering Subjects

Published on: February 8, 2014

Uncovering Hidden Dynamics of Natural Photonic Structures Using Holographic Imaging
05:45

Uncovering Hidden Dynamics of Natural Photonic Structures Using Holographic Imaging

Published on: March 31, 2022

Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution
08:41

Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution

Published on: August 16, 2012

Area of Science:

  • Optics and Photonics
  • Image Processing
  • 3D Imaging Technologies

Background:

  • Tomography enhances 3D imaging in holographic systems.
  • Two primary methods exist: object rotation and illumination beam rotation.
  • Understanding their distinct impacts on performance is crucial.

Purpose of the Study:

  • To differentiate between object rotation and illumination rotation in holographic tomography.
  • To analyze the 3D imaging performance considering diffraction effects.
  • To provide a transfer function for predicting and improving 3D image reconstruction.

Main Methods:

  • Transfer function analysis was employed.
  • Comparison of spatial frequency coverage and singularity characteristics for both rotation methods.
  • Consideration of diffraction effects in the analysis.

Main Results:

  • Illumination beam rotation yields nonisotropic spatial frequency cutoffs and a curved singularity line.
  • Object rotation provides more symmetric spatial frequency coverage but a single singularity point.
  • The two configurations exhibit fundamentally different 3D imaging performance.

Conclusions:

  • The derived 3D transfer function accurately predicts performance differences between the two holographic tomography configurations.
  • This analysis aids in optimizing 3D holographic image reconstruction strategies.
  • The choice of rotation method significantly influences the quality and characteristics of the reconstructed 3D holographic image.