Analytical performance of the selective, automatic multianalyser Olympus AU 5031
Related Experiment Video
Updated: Jun 28, 2026

Multimodal Optical Imaging Platform for Studying Cellular Metabolism
Published on: June 6, 2025
C Luley1, H G Struss, W Prellwitz
1Abteilung für Klinische Chemie und Laboratoriumsmedizin Universitätsklinik der Johannes-Gutenberg- Universität Mainz Germany.
Abstract:
The analytical performance of the selective, automatic multianalyser Olympus AU 5031 was evaluated over four months and assessed for practicability for another eight months. The evaluation followed the ECCLS guidelines. Twenty routine parameters were measured. In addition, sodium and potassium were determined on an attached flame photometric unit. Both the agreement between the eights photometers per unit and the temperature behaviour in the cuvettes was satisfactory. The imprecisions were very good. The within-run imprecision was below 1.5% for the majority of the parameters. The imprecision between days was below 5%, with the exception of creatine phosphokinase (7.4%). Glutamate dehydrogenase gave an imprecision of between 4.0% and 15.9%, which, however, is more likely due to the low activities measured rather than the fault of analyser. The recovery of the assigned values in 12 control sera was between 95% and 105% for 14 tests. Three of the remaining eight tests yielded recoveries with deviations between 10% and 18% (alanine aminotransferase, aspartate aminotransferase and bilirubin). No drift effects were observed and neither a sample carry-over nor a reagent carry-over were detected. Most tests were linear over a very wide range. Only afew tests (mainly lipase and glutamate dehydrogenase) required measurement repetitions with diluted samples. The correlation with routine instruments and tests was close. However, corrections were necessary for 14 of the 22 tests. This was not due to the performance of the analyser but, rather, to the different methodologies of compared tests, or different working temperatures on the comparison instruments, or a lack of accuracy for some of the AU tests.
Related Concept Videos
Qualitative Analysis
There are two main approaches to qualitative analysis:...
Mass Analyzers: Overview
Mass Analyzers: Common Types
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the method...