Dual NPD/ECD detection in comprehensive two-dimensional gas chromatography for multiclass pesticide analysis
Weeraya Khummueng1, Paul Morrison, Philip J Marriott
1Australian Centre for Research on Separation Science, School of Applied Sciences, RMIT University, Melbourne, Australia.
Abstract:
A comprehensive 2-D GC (GC x GC) dual detection system, coupled to nitrogen-phosphorus detection (NPD) and electron capture detection (ECD) has been developed for multiclass pesticide analysis in vegetable sample matrices. The second dimension column was connected to the parallel detectors via a microfluidic splitting device. The sample set comprised 17 organochlorine pesticides, 15 organophosphorus insecticides and 9 N-containing fungicides. Selective detection of vegetable sample extracts provides increased information content through simultaneous, correlated GC x GC plots for both ECD and NPD, which demonstrated improved separation of pesticide standards from each other, and from the sample matrix. The efficiency of NPD and ECD modes was investigated and compared; the ECD produced broader peaks, with the ECD generating greater response as measured by S/N ratio. Accuracy and precision of the approach were determined as repeatability and reproducibility for selected pesticides. The RSDs of the intraday (n = 5) and interday (3 days) analyses of the selected pesticides are less than 2.5 and 10%, respectively. The relative ratio of the ECD/NPD response is proposed to offer additional identification of individual pesticides, in addition to the (1)t(R) and (2)t(R) retention coordinates; ratios vary from 19 to over 1000 for selected pesticides that also exhibit ECD and NPD activities.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...