Point-of-care testing: false elevation of cardiac troponin I assayed in the emergency department
Related Experiment Video
Updated: Jun 28, 2026

A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
Pascal Pernet1, Bénédicte Bénéteau-Burnat, Christelle Hermand
1Service de Biochimie A, Hôpital St-Antoine, AP-HP, Saint-Antoine 75571, Paris Cedex 12, France. pascal.pernet@sat.ap-hop-paris.fr
Abstract:
In October 2007, an 18-year-old woman with no cardiac history was admitted to the emergency department for a major epigastric pain. The chest pain led to assay cardiac troponin I (cTnI) with the emergency department point-of-care testing analyzer (Stratus CS), which disclosed a value of 0.70 ng/mL, discordant with the atypical clinical presentation and the noncontributive electrocardiography. The biologist contacted for biological advice controlled cTnI with an Access II, which disclosed a value less than 0.04 ng/mL. These findings were confirmed with the discordant results of a new sample assayed on both analyzers. The interference of heterophilic antibodies (HAs) was suspected because these antianimal antibodies may lead to analytical errors in sandwich immunoassays using animal sources of immunoglobulins and can cause false-positive results. In this case, the HAs bind to the capture antibody and the conjugate antibody, simulating cTnI. The diagnosis of HA involvement was confirmed using Heterophilic Blocking Tube, a device that contains a blocking reagent composed of specific binders that attach HA. After treatment in Heterophilic Blocking Tube, the cTnI concentration measured by the Stratus CS decreased from 0.62 to 0.05 ng/mL. Finally, potentially invasive test or this patient's unnecessary hospitalization in cardiology was avoided. Our experience supports that collaboration between staffs of laboratories and medical departments owning point-of-care testing analyzers is essential to avoid mistaken diagnosis linked to analytical interferences and to ensure quality of results assayed outside the laboratory.
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Errors occurring during blood pressure monitoring
Several factors...
Acute Coronary Syndrome I: Introduction
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes