Validation of an objective device for assessing circumductive wrist motion
Related Experiment Video
Updated: Jun 28, 2026

Screening of Axonal Degeneration in Carpal Tunnel Syndrome Using Ultrasonography and Nerve Conduction Studies
Published on: January 11, 2019
Orrin I Franko1, Shalini Lal, Thierry Pauyo
1Harvard Medical School, Boston, MA 02215, USA.
Purpose:
Circumduction of the wrist consists of a circular motion combining flexion, extension, and radioulnar deviation without simultaneous supination or pronation of the forearm. This pattern of flexion-extension and radial-ulnar deviation coupling is vital in common tasks; however, its evaluation in hand clinics is limited by the availability and ease of current tools. We present the construct, criterion, test-retest, and inter-rater validity of a new circumduction measurement device.
Methods:
Splint volunteers (n = 42) and hand clinic patients (n = 51) were studied to assess different aspects of validity and reliability for the circumduction jig. Known-group validation was used to assess construct validity and demonstrate the ability of the device to differentiate between patients with lesser or greater circumduction values. Criterion validity was demonstrated by comparing the circumduction measures of the device to flexion, extension, ulnar deviation, and radial deviation. Test-retest reliability was established by comparing the results of repeated circumduction measures for the hand clinic patients by 2 blinded, independent researchers, and inter-rater reliability was determined by evaluating the correlation in circumduction measures taken on the same patient by different blinded, independent researchers.
Results:
Circumduction measurements significantly decreased (test for trend, p < .01) across the 3 different treatments that represented progressively reduced range of motion, establishing construct validity of the device. Flexion, extension, and radioulnar deviation all correlated significantly with circumduction; the correlation values ranged from 0.46 to 0.82 (p < .01) among all subjects (93 subjects, 228 measurements). Intra-rater reliability was 0.98 (p < .01) for both evaluators, and inter-rater reliability was 0.94 (p < .01).
Conclusions:
The present validation study demonstrated criterion, construct, test-retest, and inter-rater reliability for a newly designed circumduction measurement device.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: