The effect of solvent on the analysis of secondary organic aerosol using electrospray ionization mass spectrometry
Related Experiment Video
Updated: Jan 21, 2026

Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Adam P Bateman1, Maggie L Walser, Yury Desyaterik
1Department of Chemistry, University of California, Irvine, Irvine, California 92617-2025, USA.
Abstract:
This study examined the effect of solvent on the analysis of organic aerosol extracts using electrospray ionization mass spectrometry (ESI-MS). Secondary organic aerosol (SOA) produced by ozonation of d-limonene, as well as several organic molecules with functional groups typical for OA constituents, were extracted in methanol, d3-methanol, acetonitrile, and d3-acetonitrile to investigate the extent and relative rates of reactions between analyte and solvent. High resolution ESI-MS showed that reactions of carbonyls with methanol produce significant amounts of hemiacetals and acetals on time scales ranging from several minutes to several days, with the reaction rates increasing in acidified solutions. Carboxylic acid groups were observed to react with methanol resulting in the formation of esters. In contrast acetonitrile extracts showed no evidence of reactions with analyte molecules, suggesting that acetonitrile is the preferred solvent for SOA extraction. The use of solvent-analyte reactivity as a tool for the improved characterization of functional groups in complex organic mixtures was demonstrated. Direct comparison between mass spectra of the same SOA samples extracted in methanol versus acetonitrile was used to estimate the lower limits for the relative fractions of carbonyls (> or = 42%) and carboxylic acids (> or = 55%) in d-limonene SOA.
More Related Videos
09:18Time-resolved ElectroSpray Ionization Hydrogen-deuterium Exchange Mass Spectrometry for Studying Protein Structure and Dynamics
Published on: April 17, 2017
08:54Characterizing Bacterial Volatiles using Secondary Electrospray Ionization Mass Spectrometry SESI-MS
Published on: June 8, 2011
Related Concept Videos
Mass Spectrometry: Overview
Tandem Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Secondary Lymphoid Organs
The spleen is a vital organ in the lymphatic system, nestled in the upper left side of the abdomen. It is composed of two primary regions: the red pulp and the white pulp, each having distinct functions. The red pulp performs a significant role in blood filtration. It efficiently purges the blood of old or damaged red blood cells and...