Taking NIR calibrations of feed compounds from the laboratory to the process: calibration transfer between
Elvira Fernández-Ahumada1, Ana Garrido-Varo, José E Guerrero
1Department of Animal Production, University of Córdoba, Campus Rabanales, N-IV, Km 396, 14014 Córdoba, Spain. g82feahe@uco.es
Abstract:
In the context of current demands in the animal feed industry for controls and analyses, the use of instruments that may be applied on the process line has acquired a significant interest. A key aspect is that the calibrations developed for quality control with instruments sited in the laboratory (at-line) must be transferred to instruments that will be used in the plant itself (online). This study evaluates the standardization and the calibration transfer between a grating monochromator instrument (predispersive) designed for laboratory analysis and a diode array instrument (postdispersive) more adapted to process conditions. Two procedures that correct differences between spectra of two instruments were tested: the patented algorithm by Shenk and Westerhaus and piecewise direct standardization (PDS). Although results were slightly better with PDS, both methods achieved good spectral matching between the two instruments, with levels of repeatability similar to that of the grating instrument itself. The calibration transfer was evaluated in terms of the standard error of prediction (SEP), which was considerably reduced after standardization. However, final calibration models to be used in the diode array instrument must contain spectra from both types of instruments to give acceptable prediction accuracy.
More Related Videos
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...