Lesion conspicuity and efficiency of CT colonography with electronic cleansing based on a three-material transition
Iwo W O Serlie1, Ayso H de Vries, Lucas J van Vliet
1Present address: Clinical Science and Advanced Development, Healthcare Informatics, Philips Medical Systems Nederland, Veenpluis 4-6, 5684 PC, Best, The Netherlands.
Objective:
The purpose of this article is to report the effect on lesion conspicuity and the practical efficiency of electronic cleansing for CT colonography (CTC).
Materials And Methods:
Patients were included from the Walter Reed Army Medical Center public database. All patients had undergone extensive bowel preparation with fecal tagging. A primary 3D display method was used. For study I, the data consisted of all patients with polyps > or = 6 mm. Two experienced CTC observers (observer 1 and observer 2) scored the lesion conspicuity considering supine and prone positions separately. For study II, data consisted of 19 randomly chosen patients from the database. The same observers evaluated the data before and after electronic cleansing. Evaluation time, assessment effort, and observer confidence were recorded.
Results:
In study I, there were 59 lesions partly or completely covered by tagged material (to be uncovered by electronic cleansing) and 70 lesions surrounded by air (no electronic cleansing required). The conspicuity did not differ significantly between lesions that were uncovered by electronic cleansing and lesions surrounded by air (observer 1, p < 0.5; observer 2, p < 0.6). In study II, the median evaluation time per patient after electronic cleansing was significantly shorter than for original data (observer 1, 20 reduced to 12 minutes; observer 2, 17 reduced to 12 minutes). Assessment effort was significantly smaller for both observers (p < 0.0000001), and observer confidence was significantly larger (observer 1, p < 0.007; observer 2, p < 0.0002) after electronic cleansing.
Conclusion:
Lesions uncovered by electronic cleansing have comparable conspicuity with lesions surrounded by air. CTC with electronic cleansing sustains a shorter evaluation time, lower assessment effort, and larger observer confidence than without electronic cleansing.
More Related Videos
03:43Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
06:28E-Patient Counseling Trial (E-PACO): Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Endoscopic Procedures III: Video Capsule Endoscopy