Related Experiment Video
Updated: Jun 28, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Temporal and multiinstitutional quality assessment of CT colonography
Robert L Van Uitert1, Ronald M Summers, Jacob M White
1Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bldg. 10, Rm. 1C368X MSC 1182, Bethesda, MD 20892-1182, USA.
Objective:
The purpose of this study was to investigate the variability of CT colonography (CTC) scan quality obtained within and between institutions by using previously validated automated quality assessment (QA) software that assesses colonic distention and surface area obscured by residual fluid.
Materials And Methods:
The CTC scans of 120 patients were retrospectively selected, 30 from each of four institutions. The bowel preparation included oral contrast material for fecal and fluid tagging. Patients at one institution (institution 4) drank half the amount of oral contrast material compared with the patients at the other three institutions. Fifteen of the CTC scans were from the beginning of the protocol studied at each institution and 15 scans were from the same protocol acquired approximately 1 year later in the study. We used previously validated QA software to automatically measure the mean distention and residual fluid of each of five colonic segments (ascending, transverse, descending, sigmoid, and rectum). Adequate distention was defined as a colonic diameter of at least 2 cm. Residual fluid was determined by the percentage of colonic surface area covered by fluid. We compared how the quality varied across multiple institutions and over time within the same institution.
Results:
No significant difference in the amount of colonic distention among the four institutions was found (p = 0.19). However, the distention in the prone position was significantly greater than the distention in the supine position (p < 0.001). Patients at institution 4 had about half the amount of residual colonic fluid compared with patients at the other three institutions (p < 0.01). The sigmoid and descending colons were the least distended segments, and the transverse and descending colons contained the most fluid on the prone and supine scans, respectively. More recently acquired studies had greater distention and less residual fluid, but the differences were not statistically significant (p = 0.30 and p = 0.96, respectively).
Conclusion:
Across institutions, a significant difference can exist in bowel preparation quality for CTC. This study reaffirms the need for standardized bowel preparation and quality monitoring of CTC examinations to reduce poor CTC performance.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...