Related Experiment Video
Updated: Jun 28, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Dispersive liquid-liquid microextraction method based on solidification of floating organic drop combined with gas
1Department of Chemistry, National Tsing Hua University, Hsinchu 30013, Taiwan.
Abstract:
A simple dispersive liquid-liquid microextraction (DLLME) method based on solidification of a floating organic drop (DLLME-SFO) technique combined with gas chromatography/electron-capture detection (GC/ECD) or gas chromatography/mass spectrometry (GC/MS) has been developed. The proposed method is simple, low in cost, and of high precision. It overcomes the most important problem in DLLME, the high-toxic solvent used. Halogenated organic compounds (HOCs) in water samples were determined as the model compounds. The parameters optimized for the DLLME-SFO technique were as follows: A mixture of 0.5 mL acetone, containing 10 microL 2-dodecanol (2-DD-OH), was rapidly injected by syringe into the 5 mL water sample. After centrifugation, the fine 2-DD-OH droplets (8+/-0.5 microL) were floated at the top of the screwcap test tube. The test tube was then cooled in an ice bath. After 5 min the 2-DD-OH solvent had solidified and was then transferred into a conical vial; it melted quickly at room temperature and 3 microL (for GC/ECD) or 2 microL (for GC/MS) of it was injected into a gas chromatograph for analysis. The limit of detection (LOD) for this technique was 0.005-0.05microgL(-1) for GC/ECD and was 0.005-0.047 microgL(-1) for GC/MS, respectively. The linear range of the calibration curve of DLLME-SFO was from 0.01 to 500 microgL(-1) with a coefficient of estimation (r2)>0.996 for GC/ECD and was from 0.02 to 500 microgL(-1) with a coefficient of estimation (r2)>0.996 for GC/MS.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
High-Performance Liquid Chromatography: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...