Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Adaptive singular value cancelation of ventricular activity in single-lead atrial fibrillation electrocardiograms
Raúl Alcaraz1, José Joaquín Rieta
1Innovation in Bioengineering Research Group, University of Castilla-La Mancha, Campus Universitario, 16071, Cuenca, Spain. raul.alcaraz@uclm.es
Abstract:
The proper analysis and characterization of atrial fibrillation (AF) from surface electrocardiographic (ECG) recordings requires to cancel out the ventricular activity (VA), which is composed of the QRS complex and the T wave. Historically, for single-lead ECGs, the averaged beat subtraction (ABS) has been the most widely used technique. However, this method is very sensitive to QRST wave variations and, moreover, high-quality cancelation templates may be difficult to obtain when only short length and single-lead recordings are available. In order to overcome these limitations, a new QRST cancelation method based on adaptive singular value cancelation (ASVC) applied to each single beat is proposed. In addition, an exhaustive study about the optimal set of complexes for better cancelation of every beat is also presented for the first time. The whole study has been carried out with both simulated and real AF signals. For simulated AF, the cancelation performance was evaluated making use of a cross-correlation index and the normalized mean square error (nmse) between the estimated and the original atrial activity (AA). For real AF signals, two additional new parameters were proposed. First, the ventricular residue (VR) index estimated the presence of ventricular activity in the extracted AA. Second, the similarity (S) evaluated how the algorithm preserved the AA segments out of the QRST interval. Results indicated that for simulated AF signals, mean correlation, nmse, VR and S values were 0.945 +/- 0.024, 0.332 +/- 0.073, 1.552 +/- 0.386 and 0.986 +/- 0.012, respectively, for the ASVC method and 0.866 +/- 0.042, 0.424 +/- 0.120, 2.161 +/- 0.564 and 0.922 +/- 0.051 for ABS. In the case of real signals, the mean VR and S values were 1.725 +/- 0.826 and 0.983 +/- 0.038, respectively, for ASVC and 3.159 +/- 1.097 and 0.951 +/- 0.049 for ABS. Thus, ASVC provides a more accurate beat-to-beat ventricular QRST representation than traditional techniques. As a consequence, VA cancelation is optimized and the AA can be extracted more precisely. Finally, the study has proven that optimal VA cancelation is achieved when a number between 20 and 30 complexes is selected following a correlation-based strategy.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
09:17High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...