Magnetic resonance imaging (MRI) provides superior visualization of the prostate, its substructure, surrounding tissues, and, most important, focal lesions or cancer. The purpose of our canine study was to demonstrate the feasibility of a low-field (0.35 T) transperineal system that enables precise MR image guidance of prostate interventions. The canines were placed in the right lateral decubitus position. Template reconstruction, trajectory planning, contouring were based on T2-weighted FSE images. For image guidance and target confirmation, fast gradient spoiled-echo (FSPGR) sequence was used. MR compatible coaxial needles were manually inserted through the perineum to the base of the prostate. After satisfactory position was confirmed, brachytherapy catheters were placed through the coaxial needles. The mean deviation of the needle displacements was 2.9 mm with a median value of 2.7 mm. 97% of the errors were less than 4.0 mm. The needle placement accuracy was modelled by the Rayleigh distribution with a sigma value of 2.3 mm. Visual confirmation of needle placements was demonstrated on pathology tissue slices. The time needed for each step was: anaesthesia - 15 min, setup and positioning - 15 min, initial imaging - 15 min, template registration, projection - 15 min, contouring, trajectory planning, insertion of 12 needles - 60 min Based on our canine experiences our method seems to be a promising approach for performing feasible, accurate, reliable and high-quality prostate MR guidance within a reasonable time span.
Insights
This study shows a low-field (0.35 T) transperineal system is feasible for precise Magnetic Resonance Imaging (MRI) guided prostate interventions in canines. The system achieved accurate needle placement, proving promising for future prostate cancer treatments.
Area of Science:
- Urology
- Medical Imaging
- Interventional Radiology
Background:
- Magnetic Resonance Imaging (MRI) offers excellent visualization of prostate anatomy and lesions.
- Accurate guidance is crucial for effective prostate interventions like brachytherapy.
Purpose of the Study:
- To demonstrate the feasibility of a low-field (0.35 T) transperineal system for precise MRI-guided prostate interventions.
- To evaluate the accuracy and reliability of this system in a canine model.
Main Methods:
- Utilized T2-weighted FSE images for planning and fast gradient spoiled-echo (FSPGR) sequences for real-time guidance.
- Employed MR-compatible coaxial needles inserted transperineally for brachytherapy catheter placement.
- Validated needle placement accuracy through pathology examination.
Main Results:
- Achieved a mean needle displacement deviation of 2.9 mm (median 2.7 mm), with 97% of errors < 4.0 mm.
- Needle placement accuracy was modeled by Rayleigh distribution (sigma = 2.3 mm).
- Demonstrated feasibility within a reasonable time frame (total procedure time approx. 2.5 hours).
Conclusions:
- The low-field transperineal MRI guidance system is a feasible, accurate, and reliable approach for prostate interventions.