Kinetic plot method as a tool to design coupled column systems producing 100,000 theoretical plates in the shortest
Deirdre Cabooter1, François Lestremau, Frédéric Lynen
1Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, B-1050 Brussels, Belgium.
Abstract:
The present paper reports on the possibility to use the kinetic plot method (KPM) to select and design the best possible system to achieve a given number (100,000) of theoretical plates for a pharmaceutical test mixture, using the information obtained from a series of single column performance measurements of sub-2microm and supra-2microm porous shell particles conducted at three different temperatures and using mixtures of acetonitrile and 0.1% formic acid in water as the mobile phase. Because the KPM involves an extrapolation to different column lengths, the quality of the design was subsequently verified by coupling several columns to achieve the optimal total column length and run the actual analysis at the calculated optimal flow rate. The prediction error was generally better than 10%, with a slightly better prediction for t(0) and N than for the retention time t(R). The sub-2microm and the porous shell particle coupled column systems achieve the 100,000 plates about equally fast, despite the fact that the former were used at 1000bar and the latter only at 600bar. The high temperature operation (80 degrees C) yielded the fastest separation in both cases, allowing to reach 100,000 plates for a component eluting at k'=2.5 in only about 15min.
More Related Videos
07:20Discovery and Synthesis Optimization of Isoreticular Al(III) Phosphonate-Based Metal-Organic Framework Compounds Using High-Throughput Methods
Published on: October 6, 2023
10:52Multiscale Sampling of a Heterogeneous Water/Metal Catalyst Interface using Density Functional Theory and Force-Field Molecular Dynamics
Published on: April 12, 2019
Related Concept Videos
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Steady, Laminar Flow Between Parallel Plates
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating within the...
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Fluid Pressure over Flat Plate of Constant Width
The resultant force...