Radiation dose evaluations during radiological contrast studies in patients with morbid obesity
O Rampado1, L Luberto, R Faletti
1Struttura Complessa Fisica Sanitaria I, ASO San Giovanni Battista e della Città di Torino (Molinette), Corso Bramante 88/90, 10126 Torino, Italy. orampado@molinette.piemonte.it
Purpose:
The purpose of this study was to evaluate the radiation dose to patients during radiological contrast studies performed after vertical banded gastroplasty (VBG) or Roux-en-Y gastric bypass (RYGBP) surgery in patients with morbid obesity.
Materials And Methods:
Dose evaluations were performed on a sample of 39 patients (32 women and 7 men) with a mean weight of 117 kg (range 68-175 kg) and a mean body mass index (BMI) of 43.7 (range 22.2-54.9). Between the second and seventh postoperative day, patients underwent radiological follow-up after oral administration of approximately 70 ml of water-soluble iodinated contrast material (Gastrografin) and images acquired in anteroposterior, right and left oblique projections with the patient upright and then supine. Exposure conditions, dose-area product (DAP) and entrance skin dose (ESD) were recorded for each procedure. On the basis of these data, the effective dose (ED) was calculated using simulation software based on the Monte Carlo method for determining the absorbed dose to organs. To assess the optimal exposure conditions and the dose contributions of fluoroscopy and radiography, the effective dose rates were also evaluated using Plexiglas phantoms of different thickness to simulate different patient sizes.
Results:
The phantom measurements showed a fourfold dose increase when passing from normal-sized patients to obese patients. Mean DAP value obtained from in-vivo measurements was 70 Gy cm(2) (range 17-147 Gy cm(2)), and mean effective dose was 21 mSv (range 5-45 mSv).
Conclusions:
When performing radiological contrast studies in patients with morbid obesity, every possible precaution should be taken to minimise patient dose. Special care should be taken to evaluate justification of the radiological procedure.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Drug Dosing: Obese Patients
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...