Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Data Reporting and Recording01:24

Data Reporting and Recording

Reporting and recording are crucial in data documentation. The timely, thorough, and accurate documentation of facts is essential when recording patient data. Failure to record findings during an assessment or interpretation of a problem will result in loss of information and make the patient document unreliable. The reader is left with general impressions if the information is not specific. A recording is documenting data of the individual's health information in a traceable, secure, and...
Holter Monitor: 24-Hour Monitoring01:23

Holter Monitor: 24-Hour Monitoring

Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
Types of Records II: Educational and Administrative Records01:18

Types of Records II: Educational and Administrative Records

Maintaining nurses' educational and administrative records in healthcare settings, including hospitals and nursing schools, is paramount. Here's a breakdown of the types of academic records mentioned:
Errors in Taping01:18

Errors in Taping

Errors in taping arise from multiple factors that can significantly impact measurement accuracy in surveying. Misalignment of the tape, often due to human error, is one primary source. A skilled rear tapeman, using a telescope, can help correct alignment by guiding the head tapeman; however, human limitations still lead to small inaccuracies. These errors may include misplacement of pins or inaccurate tape readings due to common visual confusions, such as mistaking a six for a nine. Such...
Types of Reports II: Incident or Occurrence Report01:21

Types of Reports II: Incident or Occurrence Report

An Incident or Occurrence Report in a healthcare setting is a crucial document used to record any unexpected occurrence that may or may not have affected a patient, employee, or visitor. Such reports are critical to improving patient safety and include all details leading up to and including the event.
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...
Types of Records I: Unit and Nurses Records01:27

Types of Records I: Unit and Nurses Records

Unit records in healthcare settings document the patient's treatment history, including interventions, medications, diagnostic and laboratory results, progress notes, personal care needs, vital signs, and other medical information. They are crucial for managing patient care, aiding healthcare professionals in providing quality treatment and informed decision-making.
Unit records can be divided into two main types: administrative records and clinical records.
Administrative records in...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Early versus delayed EKOS thrombolysis in intermediate-high risk pulmonary embolism: a retrospective multicentre analysis.

Open heart·2026
Same author

Safety and efficacy of thrombolysis with the EkoSonic Endovascular System for intermediate-high risk pulmonary embolism during on- and off-hours: a multicenter study.

Clinical research in cardiology : official journal of the German Cardiac Society·2025
Same author

[Dizziness due to cardiovascular and internal diseases].

MMW Fortschritte der Medizin·2025
Same author

[Indications for loop recorder implantation for syncope].

Herzschrittmachertherapie & Elektrophysiologie·2018
Same author

[Advanced classification for cardiovascular devices].

Herzschrittmachertherapie & Elektrophysiologie·2016
Same author

[Diagnostic cardiovascular implants: Implantable loop recorder/pulmonary artery pressure sensor].

Herzschrittmachertherapie & Elektrophysiologie·2016
Same journal

[Extrasystoles in endurance athletes].

Herzschrittmachertherapie & Elektrophysiologie·2026
Same journal

[AI-Assisted ECG diagnostics : Classical test statistics still apply].

Herzschrittmachertherapie & Elektrophysiologie·2026
Same journal

[Perioperative complications during transvenous pacemaker and defibrillator implantation].

Herzschrittmachertherapie & Elektrophysiologie·2026
Same journal

Herzschrittmachertherapie & Elektrophysiologie·2026
Same journal

[Late complications after atrial fibrillation ablation : Diagnosis and management].

Herzschrittmachertherapie & Elektrophysiologie·2026
Same journal

[Position paper of the German Society of Cardiology-quality criteria for performing catheter ablation of atrial fibrillation: executive summary].

Herzschrittmachertherapie & Elektrophysiologie·2026
See all related articles

Related Experiment Video

Updated: Jun 28, 2026

Measuring Engagement of Spectators of Social Digital Games
14:02

Measuring Engagement of Spectators of Social Digital Games

Published on: July 3, 2021

[Event-recorder].

Andreas Schuchert1

  • 1Friedrich-Ebert-Krankenhaus, Medizinische Klinik, Friesenstr. 11, 24534 Neumünster, Deutschland. andreas.schuchert@fek.de

Herzschrittmachertherapie & Elektrophysiologie
|October 29, 2008
PubMed
Summary
This summary is machine-generated.

Event and implantable loop recorders aid in diagnosing heart rhythm issues. Implantable loop recorders offer significant diagnostic benefits for recurrent syncope, potentially guiding pacemaker implantation.

More Related Videos

A Video Surveillance System to Monitor Breeding Colonies of Common Terns (Sterna Hirundo)
07:39

A Video Surveillance System to Monitor Breeding Colonies of Common Terns (Sterna Hirundo)

Published on: July 22, 2018

Measuring Light-Switching Behavior Using an Occupancy and Light Data Logger
05:50

Measuring Light-Switching Behavior Using an Occupancy and Light Data Logger

Published on: January 16, 2020

Related Experiment Videos

Last Updated: Jun 28, 2026

Measuring Engagement of Spectators of Social Digital Games
14:02

Measuring Engagement of Spectators of Social Digital Games

Published on: July 3, 2021

A Video Surveillance System to Monitor Breeding Colonies of Common Terns (Sterna Hirundo)
07:39

A Video Surveillance System to Monitor Breeding Colonies of Common Terns (Sterna Hirundo)

Published on: July 22, 2018

Measuring Light-Switching Behavior Using an Occupancy and Light Data Logger
05:50

Measuring Light-Switching Behavior Using an Occupancy and Light Data Logger

Published on: January 16, 2020

Area of Science:

  • Cardiology
  • Medical Devices
  • Electrocardiography

Context:

  • Patients with infrequent, short-lasting episodes of concerning symptoms require effective monitoring of heart rhythm.
  • External event recorders offer intermittent or continuous monitoring but have limitations for certain conditions like recurrent syncope.
  • The implantable loop recorder (ILR) provides long-term, continuous monitoring for up to one year.

Purpose:

  • To review the diagnostic capabilities and applications of event and implantable loop recorders.
  • To highlight the advantages of implantable loop recorders over conventional methods for diagnosing cardiac arrhythmias.
  • To discuss the role of these devices in managing conditions such as syncope, palpitations, atrial fibrillation, and seizures.

Summary:

  • Event recorders capture electrocardiogram (ECG) data correlating symptoms with heart rhythm, suitable for conscious patients with palpitations or tachycardia.
  • The implantable loop recorder (ILR) stores ECG data for up to 42 minutes pre-activation, offering a diagnostic benefit demonstrated in randomized studies.
  • ILR is particularly effective in identifying the cause of recurrent syncope of unknown origin, enabling timely pacemaker implantation.

Impact:

  • Implantable loop recorders improve diagnostic yield for unexplained syncope, leading to appropriate interventions like pacemaker implantation.
  • These devices expand diagnostic possibilities for infrequent palpitations, atrial fibrillation monitoring, and seizure evaluation.
  • Enhanced arrhythmia detection through loop recorders can significantly improve patient management and outcomes.