Related Experiment Video
Updated: Jun 28, 2026

A Technical Guide for Performing Spectroscopic Measurements on Metal-Organic Frameworks
Published on: April 28, 2023
Spectrophotometric estimation of molybdenum with disodiom cis-1,2-dicyanoetfaylene-1,2-dithiolate
1Department of Inorganic and Analytical Chemistry Jadaopw University Calcutta-32, India.
Abstract:
A rapid spectrophotometnc method is described for estimation of molybdenum by use of the molybdenum-dicyanoethytene dithiolate complex. The bright green complex has its absorption maximum at 665 nm and in 50% aqueous acetonitrilc is stable for several days at 3M hydrochloric add concentration, The estimation is more sélective if longer wavelengths and high acidity are used. Beer's law is obeyed over the range 1-16 ppm molybdenum, optimum range 4-16 ppm. The overall formation constant Of the complex with metal to ligand ratio of 1:4 is 5 +/- 2 x 10(18). The molar absorptivity is 5.05 x 10(3) l.mole(-1).cm(-1).
More Related Videos
Related Concept Videos
Complexometric Titration: Overview
Complexometric Titration: Ligands
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human eye.

