Abstract:
Platinum(IV or II) reacts with o-phenylenediamine, at pH 6.5, to form light blue solutions having maximum absorption at 703 nm. The reaction, slow at room temperature, is complete in 3-4 min at temperatures near 100 degrees . Use of dimethylformamide in the solution prevents precipitation of the reaction product. The colour is stable for at least 24 hr. Effects of heating temperature and time, pH, reagent concentration, and other variables have been studied. The system conforms to Beer's law over the concentration range investigated. Optimum concentration range for measurement in 10-mm cells is 0.4-1.4 ppm of platinum; the molar absorptivity is 9.83 x 10(3) l. mole(-1). mm(-1). Interference from foreign ions has been evaluated, and methods for removal or masking of interferences have been tested. In the colour-forming reaction, platinum(IV) is reduced by the organic reagent to platinum(II), which is then complexed with the reagent. The metal : ligand ratio of 1 : 2 was indicated by solution spectrophotometric measurements, and was confirmed on the solid reaction product by elemental analysis and by mass spectrometric examination.
Related Concept Videos
Photoluminescence: Applications
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Flame Photometry: Overview
Flame Photometry: Lab