Related Experiment Video
Updated: Jun 28, 2026

12:38
Titration ELISA as a Method to Determine the Dissociation Constant of Receptor Ligand Interaction
Published on: February 15, 2018
Statistical adjustment of parameters for potentiometric titration data.
1Department of Chemistry, Abo Akademi, SF-20500 Abo 50, Finland.
Talanta
|July 1, 1980
Summary
This study refines parameters for potentiometric titrations, focusing on stability constants and equivalence volumes. It details statistical methods for accurate data adjustment and optimization.
Area of Science:
- Analytical Chemistry
- Physical Chemistry
- Chemical Engineering
Background:
- Potentiometric titrations are crucial for determining chemical species concentrations.
- Accurate parameter estimation is essential for reliable titration data analysis.
- Existing methods may require refinement for complex titration systems.
Purpose of the Study:
- To address the statistical challenges in adjusting parameters to potentiometric titration data.
- To optimize the determination of stability constants and equivalence volumes.
- To provide guidance on error variable selection and weighting in optimization.
Main Methods:
- Statistical analysis of experimental data from potentiometric titrations.
- Parameter refinement techniques for stability constants and equivalence volumes.
- Consideration of linearized titration curves for equivalence volume determination.
Main Results:
- Developed and discussed methods for simultaneous refinement of stability constants and equivalence volumes.
- Highlighted the importance of appropriate error variable selection and weighting.
- Demonstrated the utility of linearized titration curves for precise equivalence volume calculation.
Conclusions:
- The proposed statistical methods enhance the accuracy of parameter determination in potentiometric titrations.
- Careful consideration of error variables and weighting improves optimization results.
- Linearized titration curves offer a valuable approach for accurate equivalence volume determination.
More Related Videos
Related Concept Videos
Potentiometric Titration: Overview
Potentiometric titration is a quantitative analytical technique that determines the concentration of an analyte by measuring the potential difference between the two electrodes in the solution. The endpoint of a potentiometric titration is the point at which there is a significant change in the potential difference. It occurs when the stoichiometric reaction between the analyte and the titrant is complete. The endpoint is usually determined graphically by plotting the measured potential...
Precipitation Titration: Endpoint Detection Methods
In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
In the Volhard method, a standard excess of AgNO3 is first added to the...
End Point Prediction: Gran Plot
A Gran plot is used to predict the equivalence volume or endpoint of a potentiometric or acid-base titration without reaching the endpoint. Typically, titration data is collected as a function of the titrant's volume up to a point less than the equivalence volume and then transformed into a linear format. The straight line is extended to the x-axis, indicating the necessary titrant volume to achieve the equivalence point.
For potentiometric titration, the Gran plot is created by plotting the...
For potentiometric titration, the Gran plot is created by plotting the...
EDTA: Indirect and Alkalimetric Titration
Unlike direct titration, back-titration, and displacement titration, indirect titration is an EDTA titration method for quantifying anions. In the indirect titration method, anions are precipitated as their insoluble salts with excess metal ions. The filtrate containing the excess metal ions is directly titrated with standard EDTA until the endpoint is achieved. Another approach involves extracting the metal ion and back-titrating with standard EDTA to obtain the endpoint. In this way, the...
Acid-Base Titration Curves
A titration curve is a plot of some solution property versus the amount of added titrant. For acid-base titrations, solution pH is a useful property to monitor because it varies predictably with the solution composition and, therefore, may be used to monitor the titration’s progress and detect its endpoint. Acid-base titration can be performed with a strong acid and a strong base, a strong acid and a weak base, or a strong base and a weak acid.
For a titration carried out for 25.00 mL of 0.100...
For a titration carried out for 25.00 mL of 0.100...
Titration Calculations: Strong Acid - Strong Base
Calculating pH for Titration Solutions: Strong Acid/Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then: